Investigation of Multiple, Large Area EDS Detectors on an SEM Capable of Various Mounting Geometries for Optimal EDS Analysis

نویسندگان

  • D. Edwards
  • N. Rowlands
  • D. Guarrera
  • N. Erdman
  • V. Robertson
  • R. McLaughlin
چکیده

It is common knowledge that collecting EDS data with dual large area SDD detectors from 180 degree opposing geometries has proven extremely beneficial with highly topographic samples [REF 1]. Traditionally, using high kV, the high count rates achievable from today’s SDD EDS detectors have been used to significantly reduce the time needed to acquire the statistical data necessary for X-ray analysis and mapping. Moreover, the use of low kV EDS for high spatial resolution analysis with minimized specimen damage has been recently gaining prominence [REF 2, 3]. When low kV microanalysis is performed, there can be a significant contribution from topography variations within the sample that can affect the quality and interpretation of the collected EDS data. Utilization of multiple large area EDS detectors can help alleviate some of these issues. In this paper the benefits of large area collection at low kV will be demonstrated on the next generation SEMs using conditions conducive to minimizing sample damage and contamination and to increasing spatial resolution. We will explore the benefits of multiple geometries with a variety of topographic samples. Special attention will be paid to detector positioning in these analyses and different geometries will be compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Need for Large-Area EDS Detectors for Imaging Nanoparticles in a SEM Operating in Transmission Mode

Accurate characterization of nanoparticles (NPs) with a high-resolution SEM with respect to morphology, shape and size distribution is carried out meanwhile routinely in more and more laboratories [1,2]. The valuable result of the metrological measurement of the NP size distribution -including traceability to the SI length unit was also recently demonstrated by exploiting the transmission mode ...

متن کامل

Elemental Analysis of Biological and Cryogenic Samples

Introduction Commercial production of large-area silicon drift detectors (SDDs) heralds an exciting new time in biological elemental analysis. Improved low-energy performance and higher collection efficiencies mean EDS is no longer limited by low count rates and poor solid angles. High count rates can be achieved on all types of materials, including soft biological tissues, without altering nor...

متن کامل

Comparing the Detection of Iron-Based Pottery Pigment on a Carbon-Coated Sherd by SEM-EDS and by Micro-XRF-SEM

The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SE...

متن کامل

Automated SEM Analysis in Industrial Process Control and Scientific Research

While automated SEM analysis has been used for specific tasks such as gunshot residue analysis and technical cleanliness analysis for many years, recent advances in hardware and software make it a compelling proposition for a much wider group of researchers. Automated analysis in this context refers to solutions that enable users to define analysis tasks that are then carried out repeatedly, so...

متن کامل

Comparative Performance of SDD-EDS and WDS Detectors for Quantitative Analysis of Mineral Specimens: The Next Generation Electron Microprobe

With the development of silicon drift detectors (SDD), energy dispersive x-ray emission spectrometry is now capable of making compositional measurements of comparable precision as those that have been routinely obtained by wavelength dispersive spectrometers on electron microprobes [e.g., 1]. Large area silicon drift detectors, when placed near the specimen, subtend significantly larger solid a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014