External quality assessment of the serum bactericidal test: results of a methodology/interpretation questionnaire.

نویسندگان

  • A MacGowan
  • C McMullin
  • P James
  • K Bowker
  • D Reeves
  • L White
چکیده

Two hundred microbiology laboratories in the UK took part in two separate experimental external quality assessment distributions related to the serum bactericidal test (SBT). In the first, Staphylococcus aureus NCTC 6571 (vancomycin MIC 1 mg/L), was tested against a human serum containing vancomycin 38 mg/L plus gentamicin 0.5 mg/L. In the second, Streptococcus oralis PAJ 112/4183 (penicillin MBC < or = 0.03 mg/L) and Streptococcus sanguis PAJ 107/4184 (penicillin MBC = 128 mg/L) were tested against human serum containing penicillin 15 mg/L. Respondents returned their laboratory results and a questionnaire on clinical interpretation and technical aspects. Most laboratories (194/199, 97.5%) recommend the use of the SBT in the management of infective endocarditis but only 48 (25.2%) often or always change therapy on the basis of the result. A wide range of interpretative criteria, definitions of bactericidal endpoints and methodologies are used. Performance in the first distribution was acceptable for 75% of laboratories but in the second only 34% could identify penicillin tolerance; 34 respondents reported an SBT result of < or = 2 for the tolerant strain, 81 laboratories reported one of > or = 16. Technical factors related to acceptable performance were: sonication of broth before counting the inoculum; knowing the inoculum size in cfu/mL; use of a 4-8 h broth culture to make the inoculum; incubation of recovery plates for > 36 h; use of a calibrated pipette to sample for surviving bacteria; use of measured volumes to add the inoculum. Use of uncalibrated pipettes or standard loops to recover survivors was related to poor performance. Microbiology departments in the UK should review the clinical need to perform the SBT in the light of their local circumstances and if they elect to continue to offer this test, revise their methodologies which could be producing misleading results when testing alpha-haemolytic streptococci.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UK NEQAS in antibiotic assays.

How providers of external quality assessment (EQA) programmes relate to and interact with the monitors and watchdog of clinical laboratory performance in the UK is described. With regard to the quality of antibiotic assays, the changes in methodologies and in performance quality between 1971 (when the UK NEQAS for Antibiotic Assays began) and 1999 is reviewed. How improvements in performance an...

متن کامل

I-4: External Quality Assessment - A Necessity in The Andrology Laboratory

Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...

متن کامل

تطابق نتیجه میانگین عموم و مقدار هدف14 کمیت بیوشیمی در ارزیابی کیفی خارجی آزمایشگاههای تهران، 81-1374

Background : External quality assessment referred to the survey of different laboratories' results of a unique specimen as compared with a reliable reference. These assessments have been introduced since 1988 in Iran . Results were processed according to techniques of measurement and their accuracy was checked against the reference value. Methods : We have gathered results of 14 parameters in 9...

متن کامل

The Washback Effects of High School Third Grade Exam on EFL Teachers’ Methodology, Evaluation and Attitude

Abstract: The widespread use of test scores for different educational and social decision making purposes has made the washback effect of tests a distinct educational phenomenon (Cheng, 1997).The high school third grade final exam in the general educational system of Iran has for long been a high stake test designed to assess the achievement of high school graduates in different school subjects...

متن کامل

Serum bactericidal test.

The serum bactericidal test represents one of the few in vitro tests performed in the clinical microbiology laboratory that combines the interaction of the pathogen, the antimicrobial agent, and the patient. Although the use of such a test antedates the antimicrobial era, its performance, results, and interpretation have been subject to question and controversy. Much of the confusion concerning...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of antimicrobial chemotherapy

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 1997