An unmet need for implantable cardioverter-defibrillators in New Zealand.
نویسندگان
چکیده
AIMS This study examined the prior history of all patients presenting to the regional ambulance service with community cardiac arrest to determine what proportion of these patients had prior indications for implanted cardioverter-defibrillator (ICD) therapy. METHODS AND RESULTS We reviewed the medical history of all adult patients presenting to our regional ambulance service with cardiac arrest between 1 June 2007 and 31 May 2008 (n= 144). Patients were classified as either not having an ICD indication, having a possible ICD indication, or having an ICD indication by two electrophysiologists. Eighty-seven patients (60%) had no pre-existing indication for an ICD. Twenty-two patients (15%) had a possible indication for an ICD but required further investigation to confirm this. This group consisted of 6 patients (4%) with previously documented left ventricular ejection fraction <35%, but without a measurement in the last 12 months, 14 patients (10%) with heart failure (n= 10) or syncope (n= 4) without appropriate investigations, and 2 patients with an ICD indication but with co-morbidities that required further investigation. Thirty-five patients (24%) had a documented indication for an ICD. In 11 (8%) there was no evidence of a contraindication, in 3 (2%) alternative therapy was judged more appropriate, and in 21 (15%) contraindications to ICD implantation were also present. Addition of the 11 patients with an ICD indication and the 6 patients with a documented indication requiring updated measurement, 17 patients (12%) had a prior documented ICD indication but had not been referred for this therapy. CONCLUSIONS Our observation that 12% of sudden cardiac arrest patients had prior indications for an ICD demonstrates that there is an unmet need for ICDs in New Zealand.
منابع مشابه
A national survey of clinician's knowledge of and attitudes towards implantable cardioverter defibrillators.
AIMS This study surveyed referring clinicians to identify barriers that may contribute to New Zealand's low national implantable cardioverter defibrillator (ICD) implant rate. METHODS We conducted a telephone survey of 100 cardiologists and general physicians working at 30 different New Zealand hospitals who routinely manage patients with ischaemic heart disease and heart failure. RESULTS T...
متن کاملErosive Pressure Dermatitis Associated with Cardiac Pacemaker
Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...
متن کاملImplantable cardioverter defibrillator during laser transurethral resection of the prostate
Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملRoom Temperature Synthesis of the Larger Power, High Silver Density Cathode Material Ag4V2O6F2 for Implantable Cardioverter Defibrillators
New cathode materials will lead to technological advances for implantable cardioverter defibrillators, ICDs, such as reduced size and increased performance of the device. While the industry standard silver vanadium oxide Ag2V4O11 exhibits great chemical/electrochemical stability, dense silver oxide fluoride materials are advantageous because of high crystal density that can result in an increas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 13 9 شماره
صفحات -
تاریخ انتشار 2011