Automatic tuning and matching of a small multifrequency saddle coil at 4.7 T.

نویسندگان

  • Rigoberto Pérez de Alejo
  • Carlos Garrido
  • Palmira Villa
  • Ignacio Rodriguez
  • Juan José Vaquero
  • Jesús Ruiz-Cabello
  • Manuel Cortijo
چکیده

A new circuit design for automatically tuning and matching a saddle coil for small animal imaging is presented. This design allows working at (1)H, (19)F, and (3)He resonance frequencies in a 4.7 T spectrometer. It is based on a balanced circuit with commercial variable capacity diodes controlled by a computer using digital potentiometers. The change between two different frequencies can be accurately performed in a few seconds. System Q is compared, between 140-210 MHz, to the same coil tuned and matched with high Q variable capacitors. Differences lower than 5% were found with a loaded coil. The proposed design has initially been evaluated in (19)F and (1)H NMR images acquired with a five-tube phantom. An application is also shown for the acquisition of (3)He, (19)F, and (1)H lung images in a control rat.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance

Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...

متن کامل

Whole Body Screening Using High-Temperature Superconducting MR Volume Coils:

Previous studies on HTS coils can be put into two categories: tape surface coils and thin-film surface coils[1-4]. In this study, we build a whole new Bi2Sr2Ca2Cu2O3 (Bi-2223) superconducting volume coil (length of 8 cm) designed for the mice whole body imaging at Bruker 3T MRI system. The HTS volume coil has 2.3 folds higher S/N than that of the HTS volume coil at 300K for the mice body screen...

متن کامل

Automatically tuned and matched RF transceive head coil at 7T

Introduction The transmit efficiency and receive signal-to-noise ratio (SNR) of transceive RF coils depends on how well the resonance circuit is tuned to the Larmor frequency and matched to the 50 ohm coaxial cable. Patient size variability changes the load the coil couples with and adversely impacts both tuning and matching, and subsequently the power efficiency and SNR of the coil. The loadin...

متن کامل

Automatic Varactor Tuning of Interventional RF Receiver Coils

R. Venook, G. Gold, B. Hu, G. Scott Stanford University, Stanford, CA, United States, Palo Alto Medical Foundation, Palo Alto, CA, United States Synopsis: Small, flexible RF coils are well suited for interventional applications because of their locally-high SNR and deployability. These characteristics also make such coils easily detuned/mismatched, which can hamper imaging performance. This wor...

متن کامل

An easily constructed, tuning free, ultra-broadband probe for NMR.

We have developed an easy to construct, non-resonant wideband NMR probe. The probe is of the saddle coil geometry and is designed such that the coil itself forms a transmission line. The probe thus requires no tuning or matching elements. We use the probe with a spectrometer whose duplexer circuitry employs a simple RF switch instead of the more common lambda/4 lines, so the entire probe and sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 51 4  شماره 

صفحات  -

تاریخ انتشار 2004