Steer-PROP: a GRASE-PROPELLER sequence with interecho steering gradient pulses.

نویسندگان

  • Girish Srinivasan
  • Novena Rangwala
  • Xiaohong Joe Zhou
چکیده

PURPOSE This study demonstrates a novel PROPELLER (periodically rotated overlapping parallel lines with enhanced reconstruction) pulse sequence, termed Steer-PROP, based on gradient and spin echo (GRASE), to reduce the imaging times and address phase errors inherent to GRASE. The study also illustrates the feasibility of using Steer-PROP as an alternative to single-shot echo planar imaging (SS-EPI) to produce distortion-free diffusion images in all imaging planes. METHODS Steer-PROP uses a series of blip gradient pulses to produce N (N = 3-5) adjacent k-space blades in each repetition time, where N is the number of gradient echoes in a GRASE sequence. This sampling strategy enables a phase correction algorithm to systematically address the GRASE phase errors as well as the motion-induced phase inconsistency. Steer-PROP was evaluated on phantoms and healthy human subjects at both 1.5T and 3.0T for T2 - and diffusion-weighted imaging. RESULTS Steer-PROP produced similar image quality as conventional PROPELLER based on fast spin echo (FSE), while taking only a fraction (e.g., 1/3) of the scan time. The robustness against motion in Steer-PROP was comparable to that of FSE-based PROPELLER. Using Steer-PROP, high quality and distortion-free diffusion images were obtained from human subjects in all imaging planes, demonstrating a considerable advantage over SS-EPI. CONCLUSION The proposed Steer-PROP sequence can substantially reduce the scan times compared with FSE-based PROPELLER while achieving adequate image quality. The novel k-space sampling strategy in Steer-PROP not only enables an integrated phase correction method that addresses various sources of phase errors, but also minimizes the echo spacing compared with alternative sampling strategies. Steer-PROP can also be a viable alternative to SS-EPI to decrease image distortion in all imaging planes. Magn Reson Med 79:2533-2541, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction of Image Distortion in Non-Axial Diffusion-Weighted Imaging Using Steer-PROP

Introduction: Single-shot echo-planar imaging (SS-EPI) has been widely used for diffusion imaging, primarily due to its rapid data acquisition speed, robustness against motion, and low specific absorption rate (SAR). SS-EPI, however, not only suffers from severe off-resonance effects such as magnetic susceptibility variations but also exhibits severe distortion in non-axial planes due to concom...

متن کامل

Improved ASL Imaging with 3D GRASE PROPELLER

Introduction: Arterial Spin Labeling (ASL) uses blood water as an endogenous tracer to non-invasively measure cerebral blood flow. In a previous study, Günther et al. (1) has shown a near 3-fold improvement in perfusion signal-to-noise ratio (SNR) with single-shot 3D GRASE compared to conventional 2D EPI. However, a limitation of 3D GRASE is through-plane blurring caused by T2 decay. Reducing t...

متن کامل

A Novel T2* GRASE single-shot 3D sequence for BOLD Imaging

The Gradient and Spin Echo (GRASE) pulse sequences has been used primarily for T2 weighted imaging, with the spin echoes of the CPMG sequence utilized for the center of k-space. While to date, T2 contrast has been a fundamental feature of GRASE, it is possible to obtain T2* and BOLD signal contrast mechanisms in GRASE by shifting the central region of k-space from spin echoes to gradient echoes...

متن کامل

Anatomical imaging at 7 T using 2D GRASE – A Comparison with 2D TSE

Introduction: GRASE (Gradient-and Spin-Echo) [1] imaging has recently been used successfully for perfusion measurements [2] and functional MRI [3]. However, due to known blurring and ringing artifacts [4] GRASE still awaits a breakthrough in structural imaging [5-7]. At high field strengths such as 7 T, many imaging sequences are limited in their spatial coverage per unit time, due to their hig...

متن کامل

3D single-shot VASO fMRI using a Maxwell-gradient compensated GRASE sequence

Introduction and Theory The vascular space occupancy (VASO) method [1] was recently proposed as the first fMRI method capable of detecting activation related CBV changes, without the need for a blood-pool contrast agent. We here present a new whole-brain VASO technique based on a parallel-accelerated single-shot 3D GRASE sequence. Furthermore, we propose a flow-compensated correction for concom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 79 5  شماره 

صفحات  -

تاریخ انتشار 2018