Economic Impact of Converting from Pen and 10-mL Vial to 3-mL Vial for Insulin Delivery in a Hospital Setting.
نویسندگان
چکیده
PURPOSE To compare the impact on acquisition cost and purchased volume of rapid- and short-acting insulins following conversion from 3-mL disposable pens and 10-mL vials to 3-mL vials for individual patient supply (IPS) in a hospital setting. METHODS On February 1, 2010, St. Joseph's Hospital and Medical Center of Dignity Health in Phoenix, Arizona, converted from pens to 3-mL vials for IPS subcutaneous (SC) injection and from 10-mL short-acting insulin vials to 3-mL vials for intravenous (IV) preparation. Pharmacy purchasing data were analyzed over 6-month periods before and after conversion (March 1 through August 31, 2009, and March 1 through August 31, 2010). RESULTS Before conversion, acquisition costs were $27,866 for 5,335 mL of rapid-acting insulins and $53,336 for 26,310 mL of short-acting insulins. After conversion, insulin acquisition costs were $24,211 for 5,850 mL of rapid-acting insulins (13.1% decrease in costs, 9.7% rise in volume), with cost reduction attributable to the lower cost of 3-mL vials. Acquisition costs were $17,395 for 14,700 mL of short-acting insulins after conversion (67.4% decrease in costs, 44.1% reduction in volume), with cost reduction attributable to lower cost of 3-mL vials versus pens for IPS SC injections and 10-mL vials for IV preparation. The reduction in purchased volumes of short-acting insulins may be partly due to decreased insulin use in IV preparation. CONCLUSION Conversion from pens and 10-mL vials to 3-mL vials for rapid-and short-acting insulins resulted in reduced acquisition costs and decreased use of short-acting insulin in IV preparations.
منابع مشابه
Economic impact of converting from 10-mL insulin vials to 3-mL vials and pens in a hospital setting.
PURPOSE The economic impact associated with the conversion from 10-mL vials of insulin to 3-mL vials and pens at a community hospital was assessed. METHODS Pharmacy purchasing and administrative data from Providence St. Vincent Hospital in Portland, Oregon, were used in this analysis. The hospital converted floor-stock 10-mL vials of insulin in October 2010 to individual patient supply (IPS) ...
متن کاملAnalysis of a Delivery Device Conversion for Insulin Aspart: Potential Clinical Impact in Veterans
In Brief Insulin therapies using a wide variety of delivery devices are available to accommodate individual patients' needs. In this study of veterans with diabetes, converting from insulin aspart delivered with vials and syringes to insulin aspart delivered via a pen device resulted in no significant change in A1C. Although insulin pen delivery devices offer benefits, providers should thorough...
متن کاملMedication adherence and the associated health-economic impact among patients with type 2 diabetes mellitus converting to insulin pen therapy: an analysis of third-party managed care claims data.
OBJECTIVE This study evaluated the impact on adherence, hypoglycemic events, resource utilization, and the associated health care costs of converting from administration of insulin therapy by a vial/syringe to an insulin analogue pen device in patients with type 2 diabetes mellitus. METHODS This pre-post analysis used an integrated medical and pharmacy claims database containing information f...
متن کاملSurvey of the Performance of Commercial Dose Calibrators for Measurement of 123I Activity
The accuracy with which 123I activity is measured by a dose calibrator depends on the composition and geometry of the source. The present study assessed the variability of current commercial dose calibrators in assaying liquid 123I samples. Methods: A calibration procedure for 123I measurement was performed on 177 dose calibrators (11 manufacturers) at 138 sites in North America and Europe. Usi...
متن کاملSurvey of the performance of commercial dose calibrators for measurement of ¹²³I activity.
UNLABELLED The accuracy with which (123)I activity is measured by a dose calibrator depends on the composition and geometry of the source. The present study assessed the variability of current commercial dose calibrators in assaying liquid (123)I samples. METHODS A calibration procedure for (123)I measurement was performed on 177 dose calibrators (11 manufacturers) at 138 sites in North Ameri...