Correlation between Retinal Nerve Fiber Layer Thickness Measured by GDx and Visual Field in Nonarteritic Anterior Ischemic Optic Neuropathy: A Comparison with the Contralateral Normal Eye

نویسندگان

  • Sasan Moghimi
  • Mohammad Soleimani
  • Yadollah Eslami
  • Ghasem Fakhraie
چکیده

Purpose: To evaluate the correlations between visual field (VF) defects with retinal nerve fiber layer (RNFL) thickness in nonarteritic anterior ischemic optic neuropathy (NAION) eyes, compare different GDx parameters with the other healthy contralateral eyes, and calculate receiver operating characteristic (ROC) curve for the GDx parameters Methods: Eighteen patients with unilateral NAION from at least 3 months before were enrolled. Patients' healthy eyes were considered as control. Peripapillary RNFL thickness was measured by GDx using variable corneal compensator (GDx VCC) and VF was tested using a central 24-2 program. The GDx measurements and VF test points were divided into 4 sectors and correlations of measured parameters for each nearly corresponding sector were evaluated. The two groups were compared in terms of RNFL thickness and VF sensitivity. Correlation of RNFL thickness and VF was calculated for each sector and ROC curve and sensitivities at specificity of >90% were calculated for each GDx parameter. Results: All global and most sectoral GDx parameters were significantly different in affected and normal eyes. Temporal-nasal-superior-inferior-temporal (TSNIT) average, TSNIT standard deviation (SD) and nerve fiber indicator (NFI) were significantly correlated to mean deviation (MD) in NAION group (r=0.463, 0.597, -0.713; P=0.05, <0.01, 0.001 respectively). Most of the superior GDx parameters correlated well with the inferior field MD. Superior maximum had the highest sensitivity at ≥90% specificity at best cut-off point of 0.001 (100%). Conclusion: Most of GDx parameters were correlated with corresponding VF MD in eyes with NAION. Superior maximum was the most powerful discriminator between NAION and normal eyes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of retinal nerve fiber layer measured by scanning laser polarimeter to visual field in ischemic optic neuropathy.

OBJECTIVE To evaluate the relationship between retinal nerve fiber layer (RNFL) measurement with scanning laser polarimetry (SLP) and standard automated perimetry (SAP) in nonarteritic anterior ischemic optic neuropathy (NAION). METHODS In this prospective observational case series, all subjects (28 eyes with NAION) underwent SAP and SLP. The RNFL retardation measurements and visual field tes...

متن کامل

Axonal loss in a patient with anterior ischemic optic neuropathy as measured with scanning laser polarimetry.

PURPOSE To report Nerve Fiber Analyzer (NFA/GDx; Laser Diagnostic Technologies, San Diego, California) measurements in a patient during the early phase of an anterior ischemic optic neuropathy. METHODS Case report. A 58-year old man with acute anterior ischemic optic neuropathy had repeated NFA/GDx scans of the nerve fiber layer adjacent to the optic nerve head of the involved eye, as well as...

متن کامل

Comparison of the Retinal Microvascular Density Between Open Angle Glaucoma and Nonarteritic Anterior Ischemic Optic Neuropathy.

Purpose To compare optical coherence tomography angiography (OCT-A) retinal vasculature measurements between nonarteritic anterior ischemic optic neuropathy (NAION) and open angle glaucoma (OAG) with altitudinal hemifield visual field defects. Methods This retrospective cross-sectional study included 10 NAION eyes and 16 OAG eyes, both demonstrating hemifield visual field defects, and 27 norm...

متن کامل

Differences in pupillary light reflex between optic neuritis and ischemic optic neuropathy

OBJECTIVES To determine the differences in pupillary light reflex (PLR) between the acute and chronic phases of optic neuritis (ON) and nonarteritic anterior ischemic optic neuropathy (NAION). METHODS The study included 30 patients with ON and 22 patients with NAION whose PLR were measured by a dynamic pupillometer (PLR-200; NeurOptics Inc., Irvine, USA). Age-matched controls included 58 heal...

متن کامل

Incidence of nonarteritic anterior ischemic optic neuropathy in adult Chinese: the Beijing Eye Study.

PURPOSE To determine the incidence of optic nerve damage due to nonarteritic anterior ischemic optic neuropathy (NAION) in the adult Chinese population. METHODS The Beijing Eye Study, a population-based, longitudinal study which included 4439 subjects (age 40+ years) in 2006, was repeated in 2006. In the follow-up examination, 3169 (71.4%) subjects participated. Optic disc photographs were as...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011