Simple techniques suitable for student use to record action potentials from the frog heart.
نویسنده
چکیده
Demonstrating action potentials during class experiments is very educational for science students. It is not easy, however, to obtain a stable intracellular recording of action potentials from the conventionally used skeletal muscle cells, because the tip of a glass microelectrode often comes out or breaks due to muscle contraction. Here, I present a much simpler recording method using a flexible polyethylene electrode with a wide orifice (approximately 1 mm) for a bullfrog heart beating on automaticity. Extracellular recordings of action potentials (electrocardiogram) can be obtained by placing an electrode on the cardiac surface, and transmembrane potentials can be obtained by rupturing the membrane with negative pressure, i.e., whole cell configuration. Once attached to the heart by suction, the polyethylene electrode does not easily come off during contraction of the heart. Perfusion of the heart via the postcaval vein offers us opportunities for observing the effects of either changing ionic compositions of solutions or applying drugs. The techniques shown here provide a simple and convenient way to perform a variety of class experiments.
منابع مشابه
Use of frog ventricle to examine mechanical and electrical activity of heart.
This report describes a Langendorff heart preparation, which utilizes frog rather than mammalian hearts to demonstrate both mechanical and electrical events of the cardiac cycle. The preparation is durable in that it can be maintained for several hours while being perfused with room-temperature solutions that are not supplemented with oxygen. Ventricular perfusion is achieved via a fluid-filled...
متن کامل"Neutral hydrogen survey of andromeda galaxy": addendum.
mum) and the temperature coefficient of d-c output voltage is 1 mv per degree Celsius. A negative capacitance circuit is provided which improves the overall frequency response of the amplifier but unavoidably adds noise to the input signal if large stray capacitances are compensated. Signals of 40 pv through 7 Mohm (microelectrode in saline) can be faithfully reproduced. The amplifier has been ...
متن کاملMachine learning based Visual Evoked Potential (VEP) Signals Recognition
Introduction: Visual evoked potentials contain certain diagnostic information which have proved to be of importance in the visual systems functional integrity. Due to substantial decrease of amplitude in extra macular stimulation in commonly used pattern VEPs, differentiating normal and abnormal signals can prove to be quite an obstacle. Due to developments of use of machine l...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملOptical Mapping Of Cardiac Arrhythmias
The concept of mapping rhythmic activation of the heart dates back to the beginning of last century, with initial descriptions of reentry in turtle hearts1, to the first systematic mapping of sinus rhythm and then atrial flutter by Lewis et al2. Barker et al3 were the first to map the human heart. Initial mapping was primarily performed using single probes to record activation in different regi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in physiology education
دوره 25 1-4 شماره
صفحات -
تاریخ انتشار 2001