Local choroidal blood flow in the cat by laser Doppler flowmetry.
نویسندگان
چکیده
PURPOSE To develop a procedure using a noninvasive technique that will allow the investigation of choroidal blood flow (ChBF) regulation in discrete regions of the cat eye. Validation of this procedure will provide a method to study intrinsic, neural, and pharmacologic factors that regulate regional ChBF. METHODS The technique to measure ChBF is based on laser Doppler flowmetry. However, in contrast to conventional laser Doppler flowmetry, which uses fiber-optic probes in direct contact with the tissue to deliver the laser beam and detect the scattered light, with this technique the beam is delivered through a fundus camera and the scattered light is detected in the retinal image plane of the camera. Measurements were made in 34 anesthetized cats under conditions that would ensure that the flow measured represented ChBF in the choriocapillaris: the laser beam was aimed at retinal intervascular sites in the tapetal region of the fundus; the Doppler shift power spectrum of the light scattered by the red blood cells had the shape and frequency range typical for a microvascular bed; and the recorded flow did not decrease by more than 5% when the cat was given 100% O2 to breathe for 4 minutes. The responses to various physiologic and pharmacologic stimuli were tested and compared with those obtained from retinal vessels. RESULTS Intravenous infusions of acetylcholine increased ChBF in a dose-response fashion, whereas sympathetic nerve stimulation at various frequencies decreased ChBF as predicted by previous studies. By comparison, retinal blood flow was negligibly affected by these two stimuli. In contrast to retinal blood flow, ChBF was unaffected by diffuse luminance flicker. ChBF was found to be pulsatile. The mean of the pulsatile component of ChBF represented approximately 34% of mean ChBF, a value similar to those derived from ChBF measurements in minipigs and retinal blood flow in the cat. CONCLUSIONS This study demonstrates that laser Doppler flowmetry is a valid technique for obtaining local, noninvasive, and continuous recordings of relative ChBF. Tested under steady-state conditions for blood pressure, heart rate, and acid-base balance, ChBF is stable for long periods of time, allowing the investigation of the effect of various physiologic stimuli and pharmacologic agents on this flow.
منابع مشابه
Evaluation of Carpal Tunnel Syndrome by Laser Doppler Flowmetry
Background:Autonomic disturbance can leads to blood flow changes that can be studied by various methods. Objective: To assess the blood flow changes in patients with severe carpal tunnel syndrome by laser Doppler flowmetry Methods:Ten patients with severe unilateral carpal tunnel syndrome confirmed by electrodiagnostic examination enrolled in this study. Patients comprised one man and nine wom...
متن کاملRole of nitric oxide in maintenance of basal anterior choroidal blood flow in rats.
PURPOSE The aim of this study was to use laser Doppler flowmetry to measure anterior choroidal blood flow in the anesthetized rat and to determine the role of nitric oxide (NO) in the maintenance of basal ocular blood flow in vivo. METHODS By using laser Doppler flowmetry, blood flow from the anterior choroid in pentobarbital-anesthetized rats was measured continuously. Graded single doses (0...
متن کاملInfluence of diffuse luminance flicker on choroidal and optic nerve head blood flow.
PURPOSE In the retina there is general agreement that blood flow adapts in response to different conditions of light and darkness including diffuse luminance flicker. By contrast, regulation of choroidal blood flow in response to different light conditions is still a matter of controversy. Thus, we investigated the effect of diffuse luminance flicker on choroidal and optic nerve head blood flow...
متن کاملEffects of pentoxifylline and alprostadil on ocular hemodynamics in healthy humans.
PURPOSE Alprostadil, a prostaglandin (PG)E(1) analogue and pentoxifylline, an alkylxanthine derivate, have been shown to exert vasodilatory effects in several vascular beds. The purpose of the present study was to investigate the effect of PGE(1) and pentoxifylline on the ocular circulation. METHODS A placebo-controlled, double-masked, three-way, crossover study was performed in 15 healthy ma...
متن کاملAssessment of retinal and choroidal blood flow changes using laser Doppler flowmetry in rats.
PURPOSE A new noninvasive laser Doppler flowmetry (LDF) probe (one emitting fiber surrounded by a ring of eight collecting fibers, 1-mm interaxis distance) was tested for its sensitivity to assess the retinal/choroidal blood flow variations in response to hypercapnia, hyperoxia, diverse vasoactive agents and following retinal arteries photocoagulation in the rat. MATERIALS AND METHODS After p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 35 2 شماره
صفحات -
تاریخ انتشار 1994