Targeted Transthoracic Acoustic Activation of Systemically Administered Nanodroplets to Detect Myocardial Perfusion Abnormalities.
نویسندگان
چکیده
BACKGROUND Liquid core nanodroplets containing condensed gaseous fluorocarbons can be vaporized at clinically relevant acoustic energies and have been hypothesized as an alternative ultrasound contrast agent instead of gas-core agents. The potential for targeted activation and imaging of these agents was tested with droplets formulated from liquid octafluoropropane (C3) and 1:1 mixtures of C3 with liquid decafluorobutane (C3C4). METHODS AND RESULTS In 8 pigs with recent myocardial infarction and variable degrees of reperfusion, transthoracic acoustic activation was attempted using 1.3 to 1.7 MHz low (0.2 mechanical index [MI]) or high MI (1.2 MI) imaging in real time (32-64 Hertz) or triggered 1:1 at end systole during a 20% C3 or C3C4 droplet infusion. Any perfusion defects observed were measured and correlated with delayed enhancement magnetic resonance imaging and postmortem staining. No myocardial contrast was produced with any imaging setting when using C3C4 droplets or C3 droplets during low MI real-time imaging. However, myocardial contrast was observed in all 8 pigs with C3 droplets when using triggered high MI imaging and in 5 of 6 pigs that had 1.7 MHz real time-high MI imaging. Although quantitative myocardial contrast was lower with real-time high MI imaging than 1:1 triggering, the correlation between real-time resting defect size and infarct size was good (r=0.97; P<0.001), as was the correlation with number of transmural infarcted segments by delayed enhancement imaging. CONCLUSIONS Targeted transthoracic acoustic activation of infused intravenous C3 nanodroplets is effective, resulting in echogenic and persistent microbubbles which provide real-time high MI visualization of perfusion defects.
منابع مشابه
Radiation induced myocardial perfusion abnormalities in patients with left breast cancer: A prospective study with short and long term follow up
Introduction:The external beam radiation therapy for patients with left breast cancer at the mastectomy site may cause myocardial perfusion abnormalities. We intended to study the change of these abnormalities at short and long term post radiotherapy follow up. Methods: Twenty patients with left and 20 patients with right breast cancer comprised the exposed an...
متن کاملRadiation-induced myocardial perfusion abnormalities in breast cancer patients following external beam radiation therapy
Objective(s): Radiation therapy for breast cancer can induce myocardial capillary injury and increase cardiovascular morbidity and mortality. A prospective cohort was conducted to study the prevalence of myocardial perfusion abnormalities following radiation therapy of left-sided breast cancer patients as compared to those with right–sided cancer. Methods: To minimize potential confounding fact...
متن کاملEffect of direct-current countershocks on regional myocardial contractility and perfusion. Experimental studies.
Very high energy electrical countershocks can cause morphologic damage to the myocardium. In this study we searched for functional correlates of these shock-induced morphologic changes. We used ultrasonic sonomicrometers to measure myocardial contractility and radiolabeled microspheres to assess perfusion. Acute and chronic experiments were conducted in 45 dogs, assessing the effect of both dir...
متن کاملRelationship between Baseline ECG Abnormalities and Quantitative Perfusion Parameters of Myocardial Perfusion Findings
Background: Coronary Artery Disease (CAD) is one of the major causes of mortality in most countries. Electrocardiography (ECG) and myocardial perfusion imaging (MPI) are non-invasive disgnostic tests for CAD. Finding a relationship between abnormal findings in the baseline ECG and MPI findings can be helpful in better diagnosis of CAD. Materials and Methods: The present study examined ECG of pa...
متن کاملFilter selection for 99mTc-Sestamibi myocardial perfusion SPECT imaging [Persian]
Myocardial perfusion SPECT imaging with Tc99m-sestamibi is the most accurate non-invasive means of detecting coronary artery disease and assessing the severity of perfusion abnormalities in the patients with coronary stenosis. Though simple and straight forward the results produced by the technique is very much affected by the details being used. One of the main problems with the test, wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 9 1 شماره
صفحات -
تاریخ انتشار 2016