Design and implementation of an anthropomorphic quality assurance phantom for intensity-modulated radiation therapy for the Radiation Therapy Oncology Group.

نویسندگان

  • Andrea Molineu
  • David S Followill
  • Peter A Balter
  • William F Hanson
  • Michael T Gillin
  • M Saiful Huq
  • Avraham Eisbruch
  • Geoffrey S Ibbott
چکیده

PURPOSE To design, construct, and evaluate an anthropomorphic phantom for evaluation of intensity-modulated radiation therapy (IMRT) dose planning and delivery, for protocols developed by the Radiation Therapy Oncology Group (RTOG) and other cooperative groups. METHODS AND MATERIALS The phantom was constructed from a plastic head-shaped shell and water-equivalent plastics. Internal structures mimic planning target volumes and an organ at risk. Thermoluminescent dosimeters (TLDs) and radiochromic film were used to measure the absolute dose and the dose distribution, respectively. The reproducibility of the phantom's dosimeters was verified for IMRT treatments, and the phantom was then imaged, planned, and irradiated by 10 RTOG institutions. RESULTS The TLD results from three identical irradiations showed a percent standard deviation of less than 1.6%, and the film-scanning system was reproducible to within 0.35 mm. Data collected from irradiations at 10 institutions showed that the TLD agreed with institutions' doses to within +/-5% standard deviation in the planning target volumes and +/-13% standard deviation in the organ at risk. Shifts as large as 8 mm between the treatment plan and delivery were detected with the film. CONCLUSIONS An anthropomorphic phantom using TLD and radiochromic film can verify dose delivery and field placement for IMRT treatments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comprehensive end-to-end test for intensity-modulated radiation therapy for nasopharyngeal carcinoma using an anthropomorphic phantom and EBT3 film

Background: In head and neck radiotherapy, immobilization devices can affect dose delivery. In this study, a comprehensive end-to-end test was developed to evaluate the accuracy of radiotherapy treatment. Materials and Methods: An Alderson Radiation Therapy (ART) anthropomorphic phantom with EBT3 film was used to mimic the actual patient treatment process. Ten patients treated for nasopharyngea...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

Design of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom

The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradie...

متن کامل

A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 63 2  شماره 

صفحات  -

تاریخ انتشار 2005