UV-induced carbonyl generation with formic acid for sensitive determination of nickel by atomic fluorescence spectrometry.
نویسندگان
چکیده
UV-induced carbonyl generation with formic acid is used for gaseous sample introduction into an atomic fluorescence spectrometer for the determination of ultra-trace nickel. Compared with conventional carbonyl generation, no toxic gas CO is involved in this work, and volatile Ni(CO)(4) is generated with a single reagent formic acid under the irradiation of UV light (253.7nm, 15W). The reaction conditions, including reaction medium, UV irradiation time and reaction temperature, are optimized for the best signal. Under the optimized conditions, a limit of detection of 10ngL(-1) for nickel is obtained without any analyte-pre-concentration, which is comparable to that using in situ trapping technique. Interferences from common transition metal ions, noble metal ions and mineral acids are also investigated. The proposed method is applied to the analysis of three certified reference materials and two organic acid samples for trace nickel, with analytical results in good agreement with certified values or those obtained by electrothermal atomic absorption spectrometry. This is a simple, fairly green and highly sensitive method for ultra-trace nickel determination.
منابع مشابه
On-line Preconcentration of Nickel by Carbonyl Vaporization With Flow Injection and Continuous Flow Systems in Combination With Sensitive Determination by Electrothermal Atomic Absorption Spectrometry
A sensitive method is described for the on-line determination and preconcentration of nickel using the coupling of a flow system (continuous flow and flow injection) with transversely heated electrothermal atomic absorption spectrometry. The method is based on the volatilization of nickel as nickel tetracarbonyl and its trapping on a graphite surface. The carbonyl generation is optimized by usi...
متن کاملA new vapor generation system for mercury species based on the UV irradiation of mercaptoethanol used in the determination of total and methyl mercury in environmental and biological samples by atomic fluorescence spectrometry.
A new vapor generation system for mercury (Hg) species based on the irradiation of mercaptoethanol (ME) with UV was developed to provide an effective sample introduction unit for atomic fluorescence spectrometry (AFS). Preliminary investigations of the mechanism of this novel vapor generation system were based on GC-MS and FT-IR studies. Under optimum conditions, the limits of determination for...
متن کاملSolid Phase Extraction of Ultra Trace Amounts of Ni2+ by Dimethylglyoxime (DMG) Immobilized on Column
A column of alumina modified with sodium dodecyl sulfate (SDS) and dimethylglyoxime (DMG) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (FAAS) determinations. Under optimized conditions (pH=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. The nickel collected on the column was eluted with 5 mL of 1 M nitric ac...
متن کاملSimultaneous determination of trace mercury and cadmium in tobacco samples by cold vapor generation-atomic fluorescence spectrometry
A highly sensitive and simple method was developed for the simultaneous determination of trace cadmium and mercury in tobacco samples by cold vapor generation-atomic fluorescence spectrometry equipped with an intermittent flow reactor. The reaction was accomplished with potassium tetrahydroborate(III) in aqueous solutions. A newly modified atomizer was presented on the basis of the present atom...
متن کاملAir-assisted Liquid Liquid Microextraction Combined with Graphite Furnace Atomic Absorption Spectrometry for Preconcentration and Determination of Trace Amount of Co(II) and Ni(II) Ions in Water Samples
A simple, rapid and efficient method has been developed for the extraction, preconcentration and determination of cobalt (II) and nickel (II) ions in water samples by air-assisted liquid-liquid microextraction (AALLME) coupled with graphite furnace atomic absorption spectrometry (GFAAS). In the proposed method, much less volume of an organic solvent was used as the extraction solvent in the abs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 80 3 شماره
صفحات -
تاریخ انتشار 2010