The accuracy of CBCT in measuring jaws bone density.

نویسندگان

  • M Cassetta
  • L V Stefanelli
  • S Di Carlo
  • G Pompa
  • E Barbato
چکیده

BACKGROUND The cone-beam computerized tomography (CBCT) has become widely used for oral and maxillofacial imaging, providing a good spatial resolution, gray density range, and contrast, as well as a good pixel/noise ratio. In the CBCT the dimensional accuracy is also comparable with Computer Tomography (CT), but in contrast to the CT, the gray density values of the CBCT images (voxel value [VV]) are not absolute. AIM The aim of the study was to evaluate if there is a statistically significant difference in bone density values, defined as gray density values (VV), using two different CBCT exposure radiation (8 mAs or 15 mAs). MATERIALS AND METHODS 10 dry mandibles were CBCT scanned using two different exposure radiation (8 mAs or 15 mAs). Using software and a radiographic template, the CBCT-scan images were overlapped and two datasets were created, each one giving the respective gray values (VV), of the same area with the same spatial coordinates. The quantified gray density values of the planned volume were measured and expressed as VV in two different exposure radiation scans Groups (Group A: 8 mAs; Group B: 15 mAs). For the statistical analysis, t-test was used. RESULTS The differences between the CBCT gray density values (VV) of the Groups (Group A: 8 mAs; Group B: 15 mAs) were statistically significant (p <= .05). CONCLUSIONS This study demonstrated that the use of a CBCT to evaluate the bone density of jaws is not useful when the values are taken as absolute values. In spite of the lower radiation dose and costs of CBCT, this new technique does not allow an accurate assessment of bone density.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی مقایسه‌ای دو سیستم Cone Beam CT به لحاظ دقت اندازه‌گیری خطی محل‌های قراردهی ایمپلنت در مندیبل به‌صورت In Vitro

Background and Objective: There are critical areas in the mandible that should be considered during implant placement such as inferior alveolar canal, mental foramen, and the root of the adjacent tooth. Two-dimensional images obtained from periapical, panoramic, and conventional tomography are considered in the evaluation of implant placement and bone quality. Cone-beam computed tomography (CBC...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.&nbsp; Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

Investigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study

Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...

متن کامل

The Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible

Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 16 10  شماره 

صفحات  -

تاریخ انتشار 2012