What do you mean by aortic valve area: geometric orifice area, effective orifice area, or gorlin area?
نویسندگان
چکیده
Aortic valve area can be measured by cardiac catheterization, Doppler echocardiography, or imaging planimetry to assess aortic stenosis severity. These diagnostic techniques provide the Gorlin area, the effective orifice area (EOA) and the geometric orifice area (GOA), respectively. The differences between these three parameters depend mainly on the valve inflow shape and cross-sectional area of the ascending aorta. Because the values obtained may differ noticeably in the same patient, they may lead to different estimations of stenosis severity depending on the measurement method used. It is therefore essential to be aware of the underlying fundamentals on which these parameters are based. The aim of this state-of-the-art report was to clarify these hemodynamic concepts and to underline their clinical implications. Because planimetry only provides GOA and does not characterize the flow property, this method should preferably not be used to assess stenosis severity. The most appropriate parameters for this purpose are the Gorlin area and the energy loss coefficient (E(L)Co), which corresponds to the EOA adjusted for aortic cross-sectional area. From a hemodynamic viewpoint, Doppler E(L)Co and Gorlin area both reflect the fluid energy loss induced by aortic stenosis, and describe better the increased overload imposed on the left ventricle. Although the Gorlin area and Doppler E(L)Co are equivalent, the latter parameter has the advantage of being measurable non-invasively using Doppler echocardiography.
منابع مشابه
Doppler Assessment of Prosthetic Valve Orifice Area
Background. Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. Methods and Results. Doppler-estimated valve areas were studied for their agreement with catheterderived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-2...
متن کاملDoppler assessment of prosthetic valve orifice area. An in vitro study.
BACKGROUND Although Doppler echocardiography has been shown to be accurate in assessing stenotic orifice areas in native valves, its accuracy in evaluating the prosthetic valve orifice area remains undetermined. METHODS AND RESULTS Doppler-estimated valve areas were studied for their agreement with catheter-derived Gorlin effective orifice areas and their flow dependence in five sizes (19/20-...
متن کاملCalculation of aortic valve area by Doppler echocardiography: a direct application of the continuity equation.
The continuity equation suggests that a ratio of velocities at two different cardiac valves is inversely proportional to the ratio of cross-sectional areas of the valves. To determine whether a ratio of mitral/aortic valve orifice velocities is useful in determining aortic valve area in patients with aortic stenosis, 10 control subjects and 22 patients with predominant aortic stenosis were exam...
متن کاملHydraulic estimation of stenotic orifice area: a correction of the Gorlin formula.
To determine the source of errors in the Gorlin formula for estimating stenotic valvular orifice area, we used a pulsatile flow model that emulated left ventricular and aortic pressures and flow and allowed control of ventricular outflow orifice area. After comparing orifice areas calculated by the Gorlin formula with actual orifice areas, the Gorlin formula constant (k) was found to be highly ...
متن کاملSimultaneous Determination of Aortic Valve Area by the Gorlin Formula and by Transesophageal Echocardiography Under Different Transvalvular Flow Conditions
Objectives. The purpose of this study was to determine the impact of changes in flow on aortic valve area (AVA) as measured by the Gorlin formula and transesophageal echocardiographic (TEE) planimetry. Background. The meaning of flow-related changes in AVA calculations using the Gorlin formula in patients with aortic stenosis remains controversial. It has been suggested that flow dependence of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of heart valve disease
دوره 15 5 شماره
صفحات -