Enhanced visualization of choroidal vessels using ultrahigh resolution ophthalmic OCT at 1050 nm.
نویسندگان
چکیده
In this article the ability of ultrahigh resolution ophthalmic optical coherence tomography (OCT) to image small choroidal blood vessels below the highly reflective and absorbing retinal pigment epithelium is demonstrated for the first time. A new light source (lambdac= 1050 nm, Deltalambda = 165 nm, Pout= 10 mW), based on a photonic crystal fiber pumped by a compact, self-starting Ti:Al2O3 laser has therefore been developed. Ex-vivo ultrahigh resolution OCT images of freshly excised pig retinas acquired with this light source demonstrate enhanced penetration into the choroid and better visualization of choroidal vessels as compared to tomograms acquired with a state-of-the art Ti:Al2O3 laser (Femtolasers Compact Pro, lc= 780 nm, Deltalambda= 160 nm, Pout= 400 mW), normally used in clinical studies for in vivo ultrahigh resolution ophthalmic OCT imaging. These results were also compared with retinal tomograms acquired with a novel, spectrally broadened fiber laser (MenloSystems, lambdac= 1350 nm, Deltalambda= 470 nm, Pout = 4 mW) permitting even greater penetration in the choroid. Due to high water absorption at longer wavelengths retinal OCT imaging at ~1300 nm may find applications in animal ophthalmic studies. Detection and follow-up of choroidal neovascularization improves early diagnosis of many retinal pathologies, e.g. age-related macular degeneration or diabetic retinopathy and can aid development of novel therapy approaches.
منابع مشابه
Retinal and Choroidal Imaging With 870-nm Spectral-Domain OCT Compared With 1050-nm Spectral-Domain OCT, With and Without Enhanced Depth Imaging.
PURPOSE The purpose of this study was to compare images of the retina and choroid obtained with Spectralis 1050-nm spectral-domain optical coherence tomography (SD-OCT) with and without enhanced depth imaging (EDI) to the commercially available 870-nm SD-OCT with and without EDI. METHODS Full-length 30° line scans were obtained with both 870- and 1050-nm Spectralis OCT instruments, with and w...
متن کاملHistologic correlation of pig retina radial stratification with ultrahigh-resolution optical coherence tomography.
PURPOSE To compare ultrahigh-resolution optical coherence tomography (OCT) cross-sectional images of the pig retina with histology, to evaluate the potential of ultrahigh-resolution OCT for enhanced visualization of intra- and subretinal structures. METHODS Ultrahigh-resolution OCT images were acquired with 1.4- micro m axial x 3- micro m transverse resolution from in vitro posterior eyecup p...
متن کاملIn vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.
PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3...
متن کاملUltrahigh speed 1050nm swept source/Fourier domain OCT retinal and anterior segment imaging at 100,000 to 400,000 axial scans per second.
We demonstrate ultrahigh speed swept source/Fourier domain ophthalmic OCT imaging using a short cavity swept laser at 100,000 - 400,000 axial scan rates. Several design configurations illustrate tradeoffs in imaging speed, sensitivity, axial resolution, and imaging depth. Variable rate A/D optical clocking is used to acquire linear-in-k OCT fringe data at 100 kHz axial scan rate with 5.3 um axi...
متن کاملIn vivo imaging of the rodent eye with swept source/Fourier domain OCT
Swept source/Fourier domain OCT is demonstrated for in vivo imaging of the rodent eye. Using commercial swept laser technology, we developed a prototype OCT imaging system for small animal ocular imaging operating in the 1050 nm wavelength range at an axial scan rate of 100 kHz with ~6 µm axial resolution. The high imaging speed enables volumetric imaging with high axial scan densities, measuri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Optics express
دوره 11 17 شماره
صفحات -
تاریخ انتشار 2003