Determination of Neutron Fluxes and Spectrum Shaping Factors in Irradiation Sites of Ghana’S Miniature Neutron Source Reactor (mnsr) by Activation Method After Compensation of Loss of Excess Reactivty

نویسندگان

  • R. B. M. Sogbadji
  • B. J. B. Nyarko
  • E. H. K. Akaho
  • R. G. Abrefah
چکیده

Accurate neutron flux values in irradiation channels of research reactors are very essential to their usage. The total neutron flux of the Ghana Research Reactor-1 (GHARR-1) was measured after a beryllium reflector was added to its shim to compensate for excess reactivity loss. The thermal, epithermal and fast neutron fluxes were determined by the method of foil activation. The experimental samples with and without a cadmium cover of 1-mm thickness were irradiated in the isotropic neutron field of the irradiation sites of Ghana Research Reactor-1 facility. The induced activities in the sample were measured by gamma ray spectrometry with a high purity germanium detector. The necessary correction for gamma attenuation, thermal neutrons and resonance neutron self-shielding effects were taken into account during the experimental analysis. By defining cadmium cutoff energy of 0.55 eV, Al-0.1% Au wires of negligible thickness were irradiated at 3 kW to determine the neutron fluxes of two irradiation channels, outer channel 7 and inner channel 2 whose Neutron Shaping Factor (α) were found to be (0.037 ± 0.001) and (–0.961 ± 0.034). The neutron flux ratios at the inner irradiation site 2 were found to be, (25.308 ± 3.201) for thermal to epithermal neutrons flux, (0.179 ± 0.021) for epithermal to fast neutrons flux and (4.528 ± 0.524) for thermal to fast neutrons flux, in the outer irradiation site 7, the neutron flux ratios were found to be, (40.865 ± 3.622) for thermal to epithermal neutrons flux, (0.286 ± 0.025) for epithermal to fast neutrons flux and (11.680 ± 1.030) for thermal to fast neutrons flux.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of neutron and gamma dose in the MNSR research reactor

In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...

متن کامل

بررسی تغییرات راکتیویته ناشی از نفوذ آب در سایت‌های پرتودهی راکتور MNSR توسط کد MCNP و مقایسه با نتایج تجربی

In this work, the Isfahan Miniature Neutron Source Reactor (MNSR ) has been simulated using the MCNP code, and reactivity worth of flooding the inner irradiation sites of this reactor in an accident has been calculated. Also, by inserting polyethylene capsules containing water inside the inner irradiation sites, reactivity changes of this reactor in same such accident have been measured, the re...

متن کامل

بررسی قابلیت استفاده از رآکتورMNSR اصفهان در نوترون‌تراپی با بور به کمک شبیه‌سازی M‏CNP

One of the important neutron sources for Boron Neutron Capture Therapy (BNCT) is a nuclear reactor. It needs a high flux of epithermal neutrons. The optimum conditions of the neutron spectra for BNCT are provided by the International Atomic Energy Agency (IAEA). In this paper, Miniature Neutron Source Reactor (MNSR) as a neutron source for BNCT was investigated. For this purpose, we designed a ...

متن کامل

Implementation of neutron radiography in the MNSR Low Power Research Reactor

Neutron radiography is an unique, advanced and useful non-destructive test method in various industries and researches. Nuclear reactors are powerful and stable neutron sources for the neutron radiography system. In this research, the MNSR research reactor has been used as a neutron source for a neutron radiography system, and its neutron beam parameters have been evaluated. Also, using the dir...

متن کامل

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011