Application of doubled-angle phase correction method to time-resolved step-scan FT-IR spectra
نویسندگان
چکیده
Ž . To increase the sensitivity with which time-resolved Fourier transform infrared FT-IR difference spectra are measured, the detector is often AC-coupled. Thus, the measured interferograms correspond to spectra with both positive and negative intensities. The presence of signed intensities presents problems for the standard Mertz and Forman phase correction methods. The Mertz Signed phase correction method was designed to handle signed intensities, but the smoothing inherent in calculating the phase angles at reduced resolution introduces other errors in AC-coupled spectra produced with this algorithm. These errors are evident as signal remaining along the imaginary axis after phase correction. A new approach to phase correction, the Doubled-Angle method, can directly correct the phases of transient AC-coupled spectra without the w Ž . x need for a DC interferogram M.S. Hutson, M.S. Braiman, Appl. Spectrosc. 52 1998 974 . When this method was applied to the transient AC interferograms measured after photolysis of bacteriorhodopsin, the signal was fully rotated onto the real axis following phase correction. Here, we show that the Doubled-Angle method can be applied to time-resolved difference FT-IR spectra of halorhodopsin, a more demanding biological system due to its intrinsically small differential absorption signals. q 1999 Elsevier Science B.V. All rights reserved.
منابع مشابه
Direct Phase Correction of D ifferential FT-IR Spectra
Step -scan transient F ourier tran sform infrared (FT-IR ) d ifference sp ectra are often m easured in an ac-coup led con ® guration . The resu lting differential intensity sp ectra con tain both posit ive and negative bands. This condition poses problem s for d irect phase correction by the standard M ertz and Form an methods. Restricting th e calculated phase angle to the range [ 2 p /2, p /2...
متن کاملModern Step-scan Interferometry
www.spec t roscopyon l i ne . com T he concept of step-scan mid-infrared inter ferometr y dates back to the 1960s when the first optoelectronically controlled step-scan interferometer was reported (1). In contrast to the linear change of the optical path difference (retardation) in a conventional continuous-scan interferometer, the retardation changes stepwise in a step -scan Fourier transform–...
متن کاملStep-Scan FT-IR Time-Resolved Spectroscopy in the Solid State
The use of KBr pellets as an interference-free matrix for performing time-resolved infrared (TR-IR) measurements on samples in their crystalline state is described and demonstrated. Step-scan Fourier transform infrared time-resolved spectroscopy (S2FT-IR TRS) is used to measure the infrared (IR) absorption difference ( D A, excited state minus ground state) spectra of the long-lived chargetrans...
متن کاملTime-resolved flow-flash FT-IR difference spectroscopy: the kinetics of CO photodissociation from myoglobin revisited
Fourier-transform infrared (FT-IR) difference spectroscopy has been proven to be a significant tool in biospectroscopy. In particular, the step-scan technique monitors structural and electronic changes at time resolutions down to a few nanoseconds retaining the multiplex advantage of FT-IR. For the elucidation of the functional mechanisms of proteins, this technique is currently limited to repe...
متن کاملTime-Resolved Fourier Transform Infrared Emission Spectroscopy: Application to Pulsed Discharges and Laser Ablation
1.1 Time-resolved Fourier transform infrared spectroscopy Time-resolved spectroscopy (TRS) is a wide-spectrum technique used for studying the dynamics of chemical reactions, or the dynamic properties of molecules, radicals and ions in liquid, gas and solid states. In the infrared spectral range it can be achieved by using lasers (Smith & Palmer, 2002), grating spectrometers (Rödig & Siebert, 20...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999