Mechanical Strength and Biocompatibility of Ultrafine-Grained Commercial Purity Titanium

نویسندگان

  • Yuri Estrin
  • Hyoun-Ee Kim
  • Rimma Lapovok
  • Hoi Pang Ng
  • Ji-Hoon Jo
چکیده

The effect of grain refinement of commercial purity titanium by equal channel angular pressing (ECAP) on its mechanical performance and bone tissue regeneration is reported. In vivo studies conducted on New Zealand white rabbits did not show an enhancement of biocompatibility of ECAP-modified titanium found earlier by in vitro testing. However, the observed combination of outstanding mechanical properties achieved by ECAP without a loss of biocompatibility suggests that this is a very promising processing route to bioimplant manufacturing. The study thus supports the expectation that commercial purity titanium modified by ECAP can be seen as an excellent candidate material for bone implants suitable for replacing conventional titanium alloy implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Mechanical Properties for Commercial Purity Titanium Severely Plastic Deformed by Accumulative Roll-bonding Process

In this study accumulative roll bonding (ARB) process up to 8 Cycles (equivalent strain of 6.4) at ambient temperature was used in order to improve the mechanical properties of Commercial purity titanium (CP-Ti).Several experiment has been done and Mechanical properties of specimen has been discussed. For investigating optical microscope punching and hardness test were utilized. This is the fir...

متن کامل

Investigation of Mechanical Properties for Commercial Purity Titanium Severely Plastic Deformed by Accumulative Roll-bonding Process

In this study accumulative roll bonding (ARB) process up to 8 Cycles (equivalent strain of 6.4) at ambient temperature was used in order to improve the mechanical properties of Commercial purity titanium (CP-Ti).Several experiment has been done and Mechanical properties of specimen has been discussed. For investigating optical microscope punching and hardness test were utilized. This is the fir...

متن کامل

Lanthanum-containing hydroxyapatite coating on ultrafine-grained titanium by micro-arc oxidation: A promising strategy to enhance overall performance of titanium

Titanium is widely used in biomedical materials, particularly in dental implants, because of its excellent biocompatibility and mechanical characteristics. However, titanium implant failures still remain in some cases, varying with implantation sites and patients. Improving its overall performance is a major focus of dental implant research. Equal-channel angular pressing (ECAP) can result in u...

متن کامل

Large - scale production of nano - twinned , ultrafine - grained copper

Large-scale production of high purity (99.999%), nano-twinned, and ultrafine-grained copper foils (22 m thick) was successfully implemented by the use of nanoscale multilayer technology. The process allows the production of up to fourteen 10 cm diameter foils during a single deposition run with high levels of reproducibility. Mechanical tests demonstrate that the strength of the Cu foils (σy ∼ ...

متن کامل

An Ebsd Investigation of Ultrafine-grain Titanium for Biomedical Applications (postprint)

High-resolution electron backscatter diffraction (EBSD) was used to examine the grain structure in long rods of ultrafine-grain (UFG) commercial-purity titanium produced for medical implants. The UFG material was obtained by equal channel angular pressing (ECAP) using a Conform scheme followed by rod drawing. The microstructure was found to be bimodal consisting of relatively coarse elongated g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013