Radiology corner. Answer to last month's radiology case (# 25) and image: cystic fibrosis chest X-ray findings: a teaching analog.
نویسندگان
چکیده
The abnormal chest radiograph is often perplexing, but abnormal findings can be interpreted easily with a systematic and methodical approach. The companion cases presented this month highlights two basic, but often forgotten or confused findings that have very different meanings: tram-tracks and air-bronchograms. The authors present these two cases along with the assistance of analog imaging phantoms constructed out of household materials (straw, sponge, tape and apple), and application of some contrast media. The authors believe the presented representative cases of bronchial wall thickening (in the CF case highlighted here) and the finding of tram tracks, compared to consolidation with typical airbronchograms, should make these findings conceptually clear. An organized differential accompanies each radiographic finding to complement these two specific known diagnoses.
منابع مشابه
Radiology corner. Answer to last month's radiology case (#43) and image: Mycobacterium xenopi found incidentally on MRI of the cervical spine.
The authors present a case of a 44 year old healthy pregnant (with twins) female diagnosed with Mycobacterium xenopi in her lung. A mass was incidentally noted in the right upper apex on an MRI ordered to evaluate a subluxation seen in her cervical spine appreciated on plain radiography. Mycobacterium xenopi is uncommon, especially in immunocompetent patients. The patient did have a fractured a...
متن کاملClinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment
Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...
متن کاملQuality Control Assessment of Radiology Devices in Kerman Province, Iran
Introduction Application of quality control (QC) programs at diagnostic radiology departments is of great significance for optimization of image quality and reduction of patient dose. The main objective of this study was to perform QC tests on stationary radiographic X-ray machines, installed in 14 hospitals of Kerman province, Iran. Materials and Methods In this cross-sectional study, QC tests...
متن کاملCompliance of Radiation Dose and Image Quality in a Nigerian Teaching Hospital with the European Guidelines for Pediatric Screen-Film Chest Radiography
Introduction Blue light is a part of the spectrum with the highest energy content, which can reach the retina. The damage that it can cause to the retina is called photochemical or blue-light retinal injury. For the retinal injury assessment of the photochemical and aphakic retinal hazards in the wavelength range of 300-700 nm, use of effective spectral radiance limits (W.m-2.sr-1) seems to be...
متن کاملThe Radiographic Findings in Travelers with Chest Trauma Referred to a Tertiary Hospital in South Khorasan, Iran
Introduction: Currently, trauma is the main reason of mortality among 1-44 years old people and the third common reason of death throughout all ages. The aim of this study is to examine the radiographic findings in chest trauma patients referring to the Imam Reza Hospital in Birjand during the years of 2013-2014. Methods: The patients meeting the criteria...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Military medicine
دوره 173 7 شماره
صفحات -
تاریخ انتشار 2008