The Arclight Ophthalmoscope: A Reliable Low-Cost Alternative to the Standard Direct Ophthalmoscope

نویسندگان

  • James Lowe
  • Charles R. Cleland
  • Evarista Mgaya
  • Godfrey Furahini
  • Clare E. Gilbert
  • Matthew J. Burton
  • Heiko Philippin
چکیده

Background. The Arclight ophthalmoscope is a low-cost alternative to standard direct ophthalmoscopes. This study compared the Arclight ophthalmoscope with the Heine K180 direct ophthalmoscope to evaluate its reliability in assessing the vertical cup disc ratio (VCDR) and its ease of use (EOU). Methods. Eight medical students used both the Arclight and the Heine ophthalmoscopes to examine the optic disc in 9 subjects. An EOU score was provided after every examination (a higher score indicating that the ophthalmoscope is easier to use). A consultant ophthalmologist provided the reference standard VCDR. Results. 288 examinations were performed. The number of examinations that yielded an estimation of the VCDR was significantly higher for the Arclight ophthalmoscope (125/144, 85%) compared to the Heine ophthalmoscope (88/144, 61%) (p < 0.001). The mean difference from the reference standard VCDR was similar for both instruments, with a mean of -0.078 (95% CI: -0.10 to -0.056) for the Arclight and -0.072 (95% CI: -0.097 to -0.046) for Heine (p = 0.69). The overall EOU score was significantly higher for the Arclight ophthalmoscope (p < 0.001). Conclusion. The Arclight ophthalmoscope performs as well as, and is easier to use than, a standard direct ophthalmoscope, suggesting it is a reliable, low-cost alternative.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arclight: a pocket ophthalmoscope for the 21st century.

Arclight: a pocket ophthalmoscope for the 21st century Andrew Blaikie, senior lecturer, John Sandford-Smith, emeritus consultant ophthalmologist, Sahib Y Tuteja, third year medical student,Christopher D Williams, senior lecturer, Christopher O’Callaghan, professor of respiratory and paediatric medicine University of St Andrews School of Medicine, St Andrews KY16 9TF, UK Leicester Royal Infirmar...

متن کامل

Comparison between the panoptic ophthalmoscope and the conventional direct ophthalmoscope in the detection of sight threatening diabetic retinopathy: the kuching diabetic eye study.

OBJECTIVE To determine the sensitivity and specificity of the conventional direct ophthalmoscope and the PanOptic ophthalmoscope in the detection of sight threatening retinopathy, as well as the "Ease of Use" of these equipments. METHODS 200 diabetics, newly referred from primary health physicians were examined. Fundus examinations were performed with pupil dilatation in a dark room. The exam...

متن کامل

Optic disc assessment in the emergency department: a comparative study between the PanOptic and direct ophthalmoscopes.

Optic disc assessment is an essential part of the neurological examination of acutely unwell patients. This study compares the PanOptic ophthalmoscope with the direct ophthalmoscope for accuracy of diagnosis and ease of use. Patient satisfaction was also compared for the two instruments. A single-masked prospective observational study was carried out. The authors showed that the PanOptic ophtha...

متن کامل

Mobile Phones for Fundus Photography in Ibadan, Sub Sahara Africa

The Ophthalmoscope was developed by Von Helmotz. He published his work in1851 [1]. The direct ophthalmoscope has since being further developed and re-engineered. However the field of view is limited to about 5 degrees. Most physicians are reluctant to use it and patient education was not possible with it as only the doctor sees the retina. In 1945, Charles Sheepens developed the indirect ophtha...

متن کامل

Miniature binocular indirect ophthalmoscope.

The optical principles of indirect ophthalmoscopy were mastered by Gullstrand (I 9 I I) although his ophthalmoscope did not achieve wide popularity because of its complexity and limited field of view. Schepens (I947) demonstrated his binocular indirect ophthalmoscope 2I years ago in the United States of America. The instrument described here is a further stage in simplification (Figs I and 2). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015