Real-Time Measurement of Maximal Voluntary Breath-Holding Time in Patients with Obstructive Ventilatory Defects and Normal Controls
نویسندگان
چکیده
Background: Breath-holding test has been tested in some clinical scenarios and has proved to be of clinical utility. Objectives: To determine the maximum voluntary breath-holding time in patients with obstructive ventilator defects and in normal subjects and to correlate the breath-holding times with pulmonary function tests. Methods: We conducted a case-control study including patients with obstructive ventilator defects and a control group consisted of volunteers recruited in the same hospital, with normal spirometry. Spirometry was performed using a computerized spirometer. Breath-holding test was conducted using a pneumotachograph. All measured outputs were displayed in real time on a portable computer. The maximal voluntary apnea inspiratory and expiratory times (MVAIT and MVAET) were measured. Results: A total of 35 patients with obstructive ventilatory defects (18 asthma and 17 COPD) and 16 controls met the inclusion criteria and were included in the analysis. The MVAIT was lower in COPD patients (21.6 ± 12.6 seconds) than in controls (31.5 ± 15.7 seconds) (p=0.049). MVAET was also lower in COPD cases than in controls (16.5 ± 6.0 vs 22.1 ± 7.9; p=0.030). We found positive and significant correlations between MVAIT and FVC (L) (r=0.656; p=0.004) and between MVAIT and FEV1 (L) (r=0.518; p=0.033) in COPD cases. MVAET was also correlated with FVC (L) (r=0.505; p=0.039) and FEV1 (L) (r=0.757; p<0.0001). Conclusions: MVAIT and MVAET were significant lower in patients with obstructive ventilatory defects with COPD diagnosis than in controls, and they were correlated positively with FVC and FEV1 in COPD patients. Our results provide additional evidence of usefulness of MVAIT/MVAET as pulmonary function tests. *Corresponding author: Sérgio Saldanha Menna Barreto, Hospital de Clínicas de Porto Alegre, Universidade Federal do Rio Grande do Sul (UFRGS), Brazil, Tel: 55-51-3359-8241; Fax: 55-51-3359-8001; E-mail: [email protected] Received June 20, 2012; Accepted August 02, 2012; Published August 04, 2012 Citation: Viecili RB, Silva DR, Sanches PRS, Müller AF, da Silva DP, et al.(2012) Real-Time Measurement of Maximal Voluntary Breath-Holding Time in Patients with Obstructive Ventilatory Defects and Normal Controls. J Pulmon Resp Med 2:127. doi:10.4172/2161-105X.1000127 Copyright: © 2012 Viecili RB, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
منابع مشابه
Changes in the period of no respiratory sensation and total breath-holding time in successive breath-holding trials.
1. Immediately after breath-holding at end-expiratory level, there is a certain period of no particular respiratory sensation which is terminated by the onset of an unpleasant sensation and followed by progressive discomfort during breath-holding. This period, defined as the time from the start of voluntary breath-holding to the point where the onset of an unpleasant sensation occurs, is design...
متن کاملEvaluation of breath holding in hypercapnia as a simple clinical test of respiratory chemosensitivity.
Breath holding was used as the basis of a simple test of respiratory chemosensitivity. Breath holding was begun at selected degrees of hypercapnia produced by CO2 rebreathing. In 16 healthy control subjects there was a linear regression of the log of breath-holding time on the PCO2 at the start of breath holding. Breath-holding time (BHT) and the slope of a log BHT/Pco2 plot were closely correl...
متن کاملBreath-holding time in normal subjects, snorers, and sleep apnea patients.
BACKGROUND The onset of irregular inspiratory muscle activity has been observed toward the breakpoint of the breath-holding maneuver. We wondered if this was similar to the increased respiratory effort with paradoxical breathing seen during the resolution of an apnea in obstructive sleep apnea syndrome (OSAS). STUDY OBJECTIVE To compare the breakpoint of breath holding in normal subjects, OSA...
متن کاملEffect of Dyspnea Induced by Breath-holding on Maximal Muscular Strength of Patients with COPD
[Purpose] The purpose of the present study was to clarify the effect of dyspnea induced by breath-holding on maximum muscular strength of patients with COPD. [Subjects] This study recruited 14 COPD subjects via public posting. [Methods] Dyspnea was assessed by the modified Borg scale. The subject asked to stop breathing at end-expiration and to hold their breath with a nose clip for as long as ...
متن کاملThe Evaluation of Electrocardiography Parameters Changes in Breath‐Holding Children Compared to Controls
Background Breath-holding spells (BHS) are brief periods when young children stop breathing for up to 1 minute and are widely recognized types of non-epileptic severe occasions in early stages of childhood. This study aimed to evaluate QTd and QTc changes in children with breath-holding spells compared with healthy children. <stron...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012