Dynamics of field-amplified sample stacking
نویسندگان
چکیده
Field-amplified sample stacking (FASS) uses conductivity gradients and resulting non-uniform electromigration fluxes to effect concentration increases of analyte ions. For cases where the initial sample concentration is much smaller than the background electrolyte (BGE) concentration, the ideal maximum concentration enhancement is equal to γ , the ratio of conductivity of the sample solution to that of the BGE. However, in practice both molecular diffusion and convective dispersion limit concentration enhancement. We present a theoretical and experimental study of concentration enhancement using FASS. We model the FASS process as electromigration, diffusion, and advection of two background electrolyte ions and multiple sample species across a known initial concentration gradient. Regular perturbation methods and a generalized Taylor dispersion analysis are used to derive area-averaged species conservation and electric field equations. The model predicts the spatial and temporal development of background electrolyte concentration field, electric field, and sampleion distribution of the FASS process. We have validated this model using onchip FASS experiments. We use an acidified poly(ethylene oxide) (PEO) coating to minimize dispersion due to electro-osmotic flow (EOF), and thereby evaluate the low(but finite) dispersion regime of most interest. We have used CCD-based quantitative epifliuorescence imaging to quantify unsteady concentration fields and validate the model. This experimentally validated model is useful in developing optimal designs of sample stacking assay devices.
منابع مشابه
Simultaneous determination of doxorubicin and active metabolite doxorubicinol in plasma by capillary electrophoresis and field-amplified sample stacking
A field-amplified sample stacking and capillary electrophoresis with UV detection was described for the determination of doxorubucin and doxorubicinol in human plasma. After sample pretreatment, field-amplified sample stacking method was applied for sensitive improvement. The sample was employed with an electrokinetic injection of 10 kV for 30 sec. The capillary electrophoresis separation of do...
متن کاملSingle-step Capillary Electrophoresis for Field-amplified Sample Stacking
We developed a novel single-step capillary electrophoresis (SSCE) scheme for field-amplified sample stacking (FASS) by using a hydrophilic material polymethyl methacrylate (PMMA) microchannel chip. The capillary effect was used to introduce liquids and control capillary stop valves in a partial barrier structure of the microchannel. Through the combined action of stop valves and air vents, both...
متن کاملThousandfold signal increase using field-amplified sample stacking for on-chip electrophoresis.
Field-amplified sample stacking (FASS) leverages conductivity gradients between a volume of injected sample and the background buffer to increase sample concentration. A major challenge in applying FASS to on-chip assays is the initial setup of high-conductivity gradient boundaries in the region of the injected sample volume. We have designed, fabricated, and characterized a novel FASS-capillar...
متن کاملInvestigation of internal pressure gradients generated in electrokinetic flows with axial conductivity gradients
Field amplified sample stacking (FASS) is used to increase sample concentrations in electrokinetic flows. The technique uses conductivity gradients to establish a non-uniform electric field that accumulates ions within a conductivity gradient, and can be readily integrated with capillary electrophoresis. Conductivity gradients also cause gradients in near-wall electroosmotic flow velocities. Th...
متن کاملOn-chip Field Amplified Sam under Suppressed Elec Flow Conditio
We present theoretical and experimental results for c field amplified sample stacking (FASS). We use an acid coating to minimize dispersion due to EOF. We mod dimensional electromigration and dispersion of two bac sample ion across an initial concentration gradient. Regu to solve for the concentration fields. Also, we use CCDfluorescence imaging to experimentally measure the u validate the model.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -