The complete frequency spectrum of physiological tremor can be recreated by broadband mechanical or electrical drive.

نویسندگان

  • Carlijn Andrea Vernooij
  • Martin Lakie
  • Raymond Francis Reynolds
چکیده

Two frequency peaks of variable preponderance have been reported for human physiological finger tremor. The high-frequency peak (20-25 Hz, seen only in postural tremor) is generally attributed to mechanical resonance, whereas the lower frequency peak (8-12 Hz, seen in both postural and kinetic tremor) is usually attributed to synchronous central or reflexive neural drive. In this study, we determine whether mechanical resonance could generate both peaks. In relaxed subjects, an artificial finger tremor was evoked by random mechanical perturbations of the middle finger or random electrical muscular stimulation of the finger extensor muscle. The high and the low frequencies observed in physiological tremor could both be created by either type of artificial input at appropriate input intensity. Resonance, inferred from cross-spectral gain and phase, occurred at both frequencies. To determine any neural contribution, we compared truly passive subjects with those who exhibited some electromyographic (EMG) activity in the finger extensor; artificially created tremor spectra were almost identical between groups. We also applied electrical stimuli to two clinically deafferented subjects lacking stretch reflexes. They exhibited the same artificial tremor spectrum as control subjects. These results suggest that both typical physiological finger tremor frequencies can be reproduced by random artificial input; neither requires synchronized neural input. We therefore suggest that mechanical resonance could generate both dominant frequency peaks characteristic of physiological finger tremor. The inverse relationship between the input intensity and the resulting tremor frequency can be explained by a movement-dependent reduction in muscle stiffness, a conjecture we support using a simple computational model.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Complete Frequency Spectrum of Physiological Tremor Can Be Recreated by Broad-band Mechanical or Electrical Drive. Running Title: Physiological Tremor Can Be Recreated by Broad-band Drive Aix-marseille Université Et Cnrs

16 Two frequency peaks of variable preponderance have been reported for human physiological 17 finger tremor. The high frequency peak (20-25 Hz, seen only in postural tremor) is generally 18 attributed to mechanical resonance, whereas the lower frequency peak (8-12 Hz, seen both in 19 postural and kinetic tremor) is usually attributed to synchronous central or reflexive neural 20 drive. Here, w...

متن کامل

A dominant role for mechanical resonance in physiological finger tremor revealed by selective minimization of voluntary drive and movement.

There is a debate in the literature about whether the low- and high-frequency peaks of physiological finger tremor are caused by resonance or central drive. One way to address this issue is to examine the consequences of eliminating, as far as possible, the resonant properties or the voluntary drive. To study the effect of minimizing resonance, finger tremor was recorded under isometric conditi...

متن کامل

A Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum

Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...

متن کامل

Parametric analysis of a broadband Archimedean spiral antenna with cavity

In this article an Archimedean spiral antenna is designed and analyzed that has good operation in broadband application. By analyzing this design, the effects that different parameters have on antenna operation will be studied and ways of optimization will be found.  Influences of cavity height and number of turns to obtain good matching and gain in a frequency interval of 4 to 18 GHz will be d...

متن کامل

The resonant component of human physiological hand tremor is altered by slow voluntary movements.

Limb resonance imparts a characteristic spectrum to hand tremor. Movement will alter the resonance. We have examined the consequences of this change. Rectified forearm extensor muscle EMG and physiological hand tremor were recorded. In postural conditions the EMG spectrum is relatively flat whereas the acceleration spectrum is sharply peaked. Consequently, the gain between EMG and acceleration ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurophysiology

دوره 113 2  شماره 

صفحات  -

تاریخ انتشار 2015