Inappropriate ICD Discharge Related to Electrical Muscle Stimulation in Chiropractic Therapy: A Case Report
نویسندگان
چکیده
Implantable cardioverter defibrillators (ICDs) have been shown to reduce mortality in high-risk patients. Despite several advances in programming ICDs, inappropriate shocks persist and continue to be psychologically and physically disturbing. External electromagnetic interference from electrocautery, welding, acupunctures, low-output transcutaneous electric nerve stimulators, and electronic muscle stimulators may result in inappropriate ICD sensing and shock. We present a 63-year-old female who presented to the emergency department after an ICD shock while undergoing electronic muscle stimulation in chiropractic treatment, during which light electrical pulses were sent through skin electrodes. Our case highlights the importance of recognizing methods used by alternative medicine doctors, including electrical muscle stimulation that may cause electromagnetic interference and inappropriate ICD discharge and therefore, a higher overall mortality risk.
منابع مشابه
The Effects of Intramuscular Electrical Stimulation on Clinical And Sonographic Parameters in Patient With Trigger Points: A Case Series Study
Objective: Myofascial pain syndrome is a common disorder with a prevalence of up to 85%. It is characterized by the presence of trigger points, which all people are commonly encountered at least once throughout their lifespan. Different physical therapy and medical treatments have used to manage myofascial pain syndrome. Intramuscular electrical stimulation intervention is a relatively new trea...
متن کاملInappropriate ICD discharge induced by electrical belt stimulation for muscle-building
Funding / potential competing interests: No financial support and no other potential conflict of interest relevant to this article were reported. Correspondence: Prof JJ Goy Service de cardiologie Hôpital cantonal Rue des Pensionnats 5–7 1700 Fribourg Switzerland jjgoy[at]goyman.com Abbreviations bpm beats per minute EMI electromagnetic interference ICD implantable cardioverter-defibrillator TE...
متن کاملInappropriate Shock Delivered By Implantable Cardioverter Defibrillator - Cardiac Resynchronization Therapy (ICD-CRT) Due To Myopotential Oversensing
The clinical efficacy of ICD-CRT therapy depends on accurate sensing of intracardiac signals and sensing algorithms. We report the occurrence of sensing abnormality in a patient with ICD-CRT. In this patient, oversensing of myopotentials during strenuous muscular activity resulted in an inappropriate ICD-CRT discharge. Although modern ICDs are highly effective in detecting and terminating malig...
متن کاملWhen inappropriate becomes beneficial.
We report the case of a young man who accidentally received a prolonged electric discharge from electrical wires and released the electric source with the help of an inappropriate shock from his implantable cardioverter-defibrillator (ICD), after misinterpretation of the electrical signal by the device as a ventricular tachycardia. This case illustrates the "electrical noise" phenomenon, and un...
متن کاملInappropriate cardioverter-defibrillator discharge continues to be a major problem in clinical practice.
BACKGROUND The purpose of this study was to determine the rate and causes of inappropriate rhythm detection, and to compare adequacy of ventricular arrhythmia detection by single-chamber and dual-chamber cardioverter-defibrillators (ICD). METHODS We evaluated 190 patients (age 57.2 +/- 11.2 years) with ICD. FOLLOW-UP 34.3 +/- +/- 22 months. Dual-chamber ICD was used in 54 patients. RESULT...