Preserved autoregulation of coronary flow after off-pump coronary artery bypass grafting: retrospective assessment of intraoperative transit time flowmetry with and without intra-aortic balloon counterpulsation

نویسندگان

  • Hiroyuki Nakajima
  • Atsushi Iguchi
  • Mimiko Tabata
  • Masaru Kambe
  • Masahiro Ikeda
  • Kazuhiko Uwabe
  • Toshihisa Asakura
  • Hiroshi Niinami
چکیده

BACKGROUND Intra-aortic balloon pumping (IABP) markedly increases graft flow after coronary artery bypass grafting (CABG) with cardiopulmonary bypass. We sought to delineate the effects of IABP on graft flow after off-pump CABG (OPCAB). METHODS The clinical records of 32 patients (25 male, 7 female; mean age: 70 ± 9 years) who underwent OPCAB with IABP between January 2011 and May 2015 were retrospectively reviewed. Thirteen patients (41%) had a history of myocardial infarction, and 13 patients (41%) had a history of percutaneous coronary intervention. In total, there were 76 bypass grafts with 102 distal anastomoses. These included 50 in situ or pedicled grafts and 26 aortocoronary grafts. After completion of the anastomoses, the heart was positioned normally, and graft flow with IABP was measured using transit-time flowmetry under stable circulation. Then, IABP was turned off for 30 s to a few minutes, until graft flow was constant, for measurement of flow off IABP. RESULTS The angiographic patency rate was 100% (47/47). Overall, graft flow was 55 ± 36 ml/min on IABP and 53 ± 36 ml/min off IABP (p = 0.37). The pulsatility index was 4.1 ± 2.1 on IABP and 2.7 ± 1.5 off IABP (p < 0.001). There was no significant difference in graft flow between on and off IABP for aortocoronary bypass or in situ grafts. Graft flow was 57 ± 36 ml/min on IABP and 55 ± 37 ml/min off IABP (p = 0.41) in in situ grafts and 52 ± 34 ml/min on IABP and 49 ± 35 off IABP (p = 0.41) in aortocoronary grafts. Graft flow on IABP was more than 5 ml/min greater in 28 (37%) bypass grafts, and more than 5 ml/min lower in 20 (26%) bypass grafts. CONCLUSION In contrast to previous reports for conventional CABG, graft flow after OPCAB was not necessarily increased by IABP, regardless of elevated diastolic arterial pressure. It is suggested that preserved autoregulation of coronary flow contributes to a lower impact on the heart and early functional recovery, and consequently, greater perioperative safety of OPCAB.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictive Factors for Delayed Extubation in the Intensive Care Unit after Coronary Artery Bypass Grafting; A Southern Iranian Experience

Background: Early extubation is implemented in cardiothoracic units worldwide for its advantages such as decreased mortality, morbidity, and hospitalization costs. We conducted a retrospective study to evaluate potential factors which may affect extubation time. Methods: The records of 334 eligible patients who underwent elective coronary artery bypass grafting (CABG) in 2008 in Kowsar ...

متن کامل

Off-Pump Coronary Bypass Grafting Causing Stunned Myocardium

The term "stunned myocardium" refers to abnormalities in the myocardial function following reperfusion and is common in on-pump coronary artery bypass grafting (CABG) and is exceedingly rare in off- pump CABG. A 53-year-old man presented with unstable angina due to the severe stenosis of the left anterior descending coronary artery (LAD) and the obtuse marginal. Laboratory findings and Chest X-...

متن کامل

The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery

Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods:  In thi...

متن کامل

Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery...

متن کامل

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016