When Can We Release the Amplatzer Ductal Occluder (ADO) Safely?

نویسندگان

  • Mehdi Ghaderian
  • Mahmood Merajie
  • Hodjjat Mortezaeian
  • Mohammad Yoosef Aarabi Moghadam
چکیده

BACKGROUND The ductus arteriosus connects the main pulmonary trunk to the descending aorta. The incidence of isolated patent ductus arteriosus (PDA) in full-term infants is about 1 in 2000. The Amplatzer Ductal Occluder (ADO) is recommended for PDAs with sizes larger than 2 mm. In this procedure, we must confirm the ADO position in PDA by aortogram from the arterial line. The purpose of this study was to determine the optimal release time of the ADO in the PDA closure procedure, especially in the absence of an arterial line for post-PDA aortography. METHODS This study recruited all patients scheduled to undergo PDA transcatheter closure with the ADO between September 2009 and September 2012 in our center. Age, weight, PDA diameter, systolic and diastolic pulmonic pressures, fluoroscopy time, and total angiographic time were studied. Major complications such as mortality and vascular complications were considered. RESULTS We studied 237 patients in our investigation. We had 130 female and 107 male patients at a mean age of 34.3 ± 40.6 months and mean weight of 14.2 ±7.8 kg. PDA sizes ranged from 2.1 to 6.2 mm and its mean was 3.7 ± 1.8 mm. Mean of fluoroscopy time was 11.4 ± 9.7 min and mean of total angiographic time was 42.0 ± 12.3 min. There were no significant complications. CONCLUSION We herein describe a new sign, which proved extremely helpful during our PDA closure procedures with the ADO. By considering the angle between the ADO and the cable during the procedure, the operator can release the ADO safely.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Closure of Large Patent Ductus Arteriosus Using the Amplatzer Ductal Occluder

Background: Coils are suitable for the closure of a small patent ductus arteriosus (PDA) but are not recommended for a large PDA. We reported our initial experience of transcatheter closure of a large PDA using the Amplatzer ductal occluder (ADO). Methods: From April 2002 to October 2006, all patients with ductal size greater than 3.5 mm undergoing transcatheter closure of PDA using the ADO wer...

متن کامل

Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...

متن کامل

Ductal closure using the Amplatzer duct occluder type two: experience in Port Elizabeth hospital complex, South Africa

OBJECTIVE To report outcomes in percutaneous ductal closure using the Amplatzer duct occluder type two (ADO II). METHODS Records of patients admitted for percutaneous closure of patent ductus arteriosus (PDA) were reviewed. RESULTS From May 2009 to July 2012, 36 patients were assigned to closure using the ADO II. There were 21 females and 15 males. The median age was 16.5 (2-233) months; me...

متن کامل

Successful transcatheter closure of a residual patent ductus arteriosus with complex anatomy after surgical ligation using an amplatzer ductal occluder guided by live three-dimensional transesophageal echocardiography.

Residual patent ductus arteriosus (PDA) after surgical ligation is not common, but the anatomy of the residual duct may be distorted by the surgical ligation resulting in a difficult transcatheter closure. Such distorted anatomy of the duct may not be demonstrated by the two-dimensional transesophageal echocardiography (2D TEE). Fortunately, live 3D TEE provided the precise anatomy of the elong...

متن کامل

A Retrospective Study of 1526 Cases of Transcatheter Occlusion of Patent Ductus Arteriosus

BACKGROUND Patent ductus arteriosus (PDA) is one of the most common congenital heart diseases and began to get treated by transcatheter occlusion since 1997 in China. Since then, several devices have been invented for occluding PDA. This study aimed to evaluate the technical feasibility, safety, and efficacy of transcatheter occlusion of PDA with different devices. METHODS One thousand five h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013