Inspiratory time and tidal volume during intermittent positive pressure ventilation.

نویسندگان

  • D Field
  • A D Milner
  • I E Hopkin
چکیده

We measured the tidal volume achieved during intermittent positive pressure ventilation using various inspiratory times with a minimum of 0.2 seconds. Results indicate that tidal volume shows no reduction with inspiratory times down to 0.4 seconds. An inspiratory time of 0.3 seconds, however, is likely to reduce tidal volume by 8%, and at 0.2 seconds a 22% fall may be anticipated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Leak compensation in positive pressure ventilators: a lung model study.

Leak compensating abilities of six different positive pressure ventilators commonly used to deliver noninvasive positive pressure ventilation, including the bilevel positive airway pressure (BiPAP) S/T-D and Quantum (Respironics Inc, Murrysville, PA, USA), 335 and O'NYX (Mallinckrodt Inc, St Louis, MO, USA), PLV 102 (Respironics), and Siemens Servo 900C (Siemens Inc, Danvers, MA, USA). Using a ...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

Pediatric Pulmonology 41:875–881 (2006) Synchronized Nasal Intermittent Positive Pressure Ventilation (SNIPPV) Decreases Work of Breathing (WOB) in Premature Infants With Respiratory Distress Syndrome (RDS) Compared to Nasal Continuous Positive Airway Pressure (NCPAP)

Synchronized nasal intermittent positive pressure ventilation (SNIPPV) is noninvasive respiratory support that delivers ventilator breaths via the nasal prongs.We hypothesized that SNIPPV is more effective than nasal continuous positive airway pressure (NCPAP) in premature neonates due to decreased work of breathing (WOB). Fifteen infants (BW: 1,367 325 g, GA: 29.5 2.4 weeks) were studied on (a...

متن کامل

Measuring exhaled volume with continuous positive airway pressure and intermittent mandatory ventilation. Techniques and rationale.

When patients breathe spontaneously through a ventilator circuit, a fall in airway pressure during the inspiratory cycle may increase inspiratory effort. A system of delivery which incorporates a distensible reservoir bag and delivers a constant flow of gas that is two or three times the patient's minute volume will prevent a significant drop in inspiratory airway pressure. Unfortunately, the c...

متن کامل

بررسی نیاز‌های توجهی کنترل الگوی تنفس و ارتباط آن با پیامد‌های متابولیکی تنفس در افراد سالم

Objective: Normal breathing is essential for adjustment of natural metabolism of human body. Therefore, the aim of this study was to evaluate the control of breathing pattern in normal subjects both at rest and during cognitive loading. Materials & Methods: In this quasi-experimental study, 24 healthy subjects (14 males, 10 females) were selected by simple and convenient sampling. Spirometry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 60 3  شماره 

صفحات  -

تاریخ انتشار 1985