Reproducibility of the visual evoked potential using a light-emitting diode stimulator.
نویسندگان
چکیده
The intersubject and intrasubject reproducibility of the VEP was evaluated using two different methods of producing pattern reversal--a mirror/projector system and a light-emitting diode (LED) system. Intersubject reproducibility was determined in 100 normal subjects (50 males, 50 females). Ten subjects were studied on ten different occasions over 11 months to establish intrasubject reproducibility. The two methods gave comparable results. It is concluded that the mirror/projector system has no advantages over the LED system, which is cheaper, more robust and more convenient. Most of the intersubject variability was found to be due to subject variables and it is concluded that technical improvements are unlikely to reduce further the variability of the test. A variability in the latency of P100 of up to 7.7 ms was recorded in the serial studies on the ten subjects, indicating that in longitudinal studies on patients, changes in latency must exceed 9-10 ms to be significant. With both stimulus systems, there were significant sex-related differences in latency (P50 and P100 but not N70) and amplitude (N70-P100). The extent of the difference was such that the upper limit of normal latency for P100 (2.5-3 SD from the mean) was 4.2-4.7 ms longer for males than females-a value which exceeds 1 SD. Separate control values for males and females are advisable whichever method is used to produce pattern reversal.
منابع مشابه
A study using light emitting diode goggles
We used a signal averager with light emitting diode goggles as the photostimulator to study the development of the visual evoked potentials in 40 normal neonates of between 23 and 42 weeks' gestation. All except two infants of less than 24 weeks' gestation had replicable visual evoked potentials. A negative peak of latency (mean (SD), 308 (21) msec) was present in all infants, but the developme...
متن کاملDevelopment of visual evoked potentials in neonates. A study using light emitting diode goggles.
We used a signal averager with light emitting diode goggles as the photostimulator to study the development of the visual evoked potentials in 40 normal neonates of between 23 and 42 weeks' gestation. All except two infants of less than 24 weeks' gestation had replicable visual evoked potentials. A negative peak of latency (mean (SD), 308 (21) msec) was present in all infants, but the developme...
متن کاملStimulator Selection in SSVEP-Based Spatial Selective Attention Study
Steady-State Visual Evoked Potentials (SSVEPs) are widely used in spatial selective attention. In this process the two kinds of visual simulators, Light Emitting Diode (LED) and Liquid Crystal Display (LCD), are commonly used to evoke SSVEP. In this paper, the differences of SSVEP caused by these two stimulators in the study of spatial selective attention were investigated. Results indicated th...
متن کاملMulti-target SSVEP-based BCI using Multichannel SSVEP Detection
Spatial filtering method and fast Fourier transform (FFT) based spectrum estimation method are applied to reveal the presence of steady state visual evoked potential (SSVEP) in multiple-electrodes electroencephalogram (EEG) signals used in Brain-Computer Interface (BCI) system. The SSVEP responses are elicited by visual stimuli in the form of flickering light emitting diode (LED) array and comp...
متن کاملComparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT
Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neurology, neurosurgery, and psychiatry
دوره 47 6 شماره
صفحات -
تاریخ انتشار 1984