Value and limitations of segmental analysis of stress thallium myocardial imaging for localization of coronary artery disease.

نویسندگان

  • P Rigo
  • I K Bailey
  • L S Griffith
  • B Pitt
  • R D Burow
  • H N Wagner
  • L C Becker
چکیده

This study was done to determine the value of thallium-201 myocardial scintigraphic imaging (MSI) for identifying disease in the individual coronary arteries. Segmental analysis of rest and stress MSI was performed in 133 patients with arteriographically proved coronary artery disease (CAD). Certain scintigraphic segments were highly specific (97-100%) for the three major coronary arteries: anterior wall and septum for the left anterior descending (LAD) coronary artery; the inferior wall for the right coronary artery (RCA); and the proximal lateral wall for the circumflex (LCX) artery. Perfusion defects located in the anterolateral wall in the anterior view were highly specific for proximal disease in the LAD involving the major diagonal branches, but this was not true for "septal" defects. The apical segments were not specific for any of the three major vessels. Although MSI was abnormal in 89% of these patients with CAD, it was less sensitive for identifying individual vessel disease: 63% for LAD, 50% for RCA and 21% for LCX disease (narrowings > 50%). Sensitivity increased with the severity of stenosis, but even for 100% occlusions was only 87% for LAD, 58% for RCA and 38% for LCX. Sensitivity diminished as the number of vessels involved increased: with single-vessel disease, 80% of LAD, 54% of RCA and 33% of LCX lesions were detected, but in patients with triple-vessel disease, only 50% of LAD, 50% of RCA and 16% of LCX lesions were identified. Thus, although segmental analysis of MSI can identify disease in the individual coronary arteries with high specificity, only moderate sensitivity is achieved, reflecting the tendency of MSI to identify only the most severely ischemic area among several that may be present in a heart. Perfusion scintigrams display relative distributions rather than absolute values for myocardial blood flow.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THALLIUM-201 STRESS TEST IN 156 PATIENTS WITH SUSPECTED CORONARY ARTERY DISEASE

Currently, myocardial TI-201 scintigraphy is most often performed in conjunction with exercise stress testing in patients with suspected or known CAD. Stress thallium tests were performed for 156 patients with and without old myocardial infarctions complaining of chest pain. All of them underwent contrast coronary angiography. Perfusion defects were mostly manifested as reversible defects ...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Myocardial damage of the entire ventricular region in a patient with acute myocardial infarction

Technetium-99m-pyrophosphate (99mTc-PYP) has been used, in combination with thallium-201, to estimate the site and extent of myocardial infarcts. We report a case of acute myocardial infarction with severe coronary disease in which the distribution of 99mTc-PYP was extensive. A 78-year-old man presented with dyspnea, and a diagnosis of non-ST-segment elevation acute myocar...

متن کامل

Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease

Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...

متن کامل

Comparison of dipyridamole – induced electrocardiographic changes and myocardial perfusion imaging in diagnosis of coronary artery disease [Persian]

Introduction: This study evaluated the diagnostic value of the dipyridamole induced electrocardiuogram (ECG) cahnges, comparing with myocardial perfusion imaging. Materials and Methods: 222 patinets were studied with dipyridamole infusion (based on ECG criteria) as well as Dipyridamole-myocardial perfusion imaging (MPI). Results: Abnormal dipyridamole test and abnormal MPI were noted in 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 61 5  شماره 

صفحات  -

تاریخ انتشار 1980