Finite element modeling of the left atrium to facilitate the design of an endoscopic atrial retractor.
نویسندگان
چکیده
With the worldwide prevalence of cardiovascular diseases, much attention has been focused on simulating the characteristics of the human heart to better understand and treat cardiac disorders. The purpose of this study is to build a finite element model of the left atrium (LA) that incorporates detailed anatomical features and realistic material characteristics to investigate the interaction of heart tissue and surgical instruments. This model is used to facilitate the design of an endoscopically deployable atrial retractor for use in minimally invasive, robotically assisted mitral valve repair. Magnetic resonance imaging (MRI) scans of a pressurized explanted porcine heart were taken to provide a 3D solid model of the heart geometry, while uniaxial tensile tests of porcine left atrial tissue were conducted to obtain realistic material properties for noncontractile cardiac tissue. A finite element model of the LA was constructed using ANSYS Release 9.0 software and the MRI data. The Mooney-Rivlin hyperelastic material model was chosen to characterize the passive left atrial tissue; material constants were derived from tensile test data. Finite element analysis (FEA) models of a CardioVations Port Access retractor and a prototype endoscopic retractor were constructed to simulate interaction between each instrument and the LA. These contact simulations were used to compare the quality of retraction between the two instruments and to optimize the design of the prototype retractor. Model accuracy was verified by comparing simulated cardiac wall deflections to those measured by MRI. FEA simulations revealed that peak forces of approximately 2.85 N and 2.46 N were required to retract the LA using the Port Access and prototype retractors, respectively. These forces varied nonlinearly with retractor blade displacement. Dilation of the atrial walls and rigid body motion of the chamber were approximately the same for both retractors. Finite element analysis is shown to be an effective tool for analyzing instrument/tissue interactions and for designing surgical instruments. The benefits of this approach to medical device design are significant when compared to the alternatives: constructing prototypes and evaluating them via animal or clinical trials.
منابع مشابه
Left Atrial Myxoma: A Rare Tumor in a Child
Atrial myxomas are uncommon in the pediatric population but are very important due to pursuant atrioventricular valve obstruction and systemic embolic events. Concerning multiple symptoms ranging from congestive heart failure to neurological deficits, the diagnosis of this disease is complicated. This paper reports a case of left atrium myxoma in a child treated with a surgical excision o...
متن کاملIncidence of Atrial Fibrillation after Coronary Artery Bypass Graft Surgery and Its Risk Factors in Shiraz, Iran during 2017-18
Background and Objectives: Atrial fibrillation is one of the most common disorientations after coronary artery bypass graft surgery and can affect the chance of survival in the first year after surgery. The present study aimed to determine the incidence of atrial fibrillation after coronary artery bypass graft surgery and its risk factors. Methods: This cross-sectional study was performed on...
متن کاملCor Triatriatum Sinistrum Presenting as Cyanotic Congenital Heart Disease A Rare Case Report
Cor triatriatum is an acyanotic congenital heart disease. We present a rare case of cor triatriatum sinistrum in a 6-month-old female infant who was presented with cyanosis and failure to thrive. The 2D transthoracic echocardiography and the Doppler color flow imaging showed a proximal venous chamber communicating to the distal left atrium through restrictive opening to the low-pressure, dis...
متن کاملAnalysis of non-connected piled raft foundations (NCPRF) with cushion by finite element method
For the optimum design of Piled Raft Foundations (PRF), the concept of settlement reducer piles has been applied. However, when these piles are connected to the raft, a high stress may develop in the relatively small number of piles. Therefore, an alternative approach is to disconnect the piles from the raft forming a new system called a non-connected or disconnected piled-raft foundation (NCPR...
متن کاملProposed Relationship to Design the Waffle Floor under Harmonic Vertical Loading
The design codes of building are mainly related to the strength of the building and there are no specific codes for the design of building with waffle floors for vibration sensitive equipment. The finite element model, ANSYS, is capable to consider the effects of floor thickness, the size of the bays and stiffness of the columns for analyzing the vibration of the waffle floors and vibration tra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 129 6 شماره
صفحات -
تاریخ انتشار 2007