Quantitative evaluation of axial wall taper in prepared artificial teeth.
نویسندگان
چکیده
The purpose of this study was to quantitatively evaluate the axial wall taper of prepared artificial teeth using a non-contact three-dimensional shape measuring system. A total of 54 artificial teeth prepared by pre-clinical dental students for complete cast restorations were evaluated. For quantitative analysis, five cross sections were computer-graphically placed perpendicularly to the z-axis. The surface coordinate values (x, y, z) of each cross section were converted into polar coordinate values (r, theta), which were then graphically rendered to a two-dimensional plane. At four points, each 90 degrees from the distal center point of the cross section, the axial wall taper was quantitatively calculated using a formula based on the differences in radius between the highest and lowest positions of the cross sections of the prepared tooth. The average calculated taper was 5.8 degrees in the distal region, 21.7 degrees in the buccal region, 14.9 degrees in the mesial region and 12.5 degrees in the lingual region. These results suggest that the axial wall taper of prepared teeth can be quantitatively evaluated using this measuring system.
منابع مشابه
Evaluation of Tensile Bond Strength between Dentin and Metallic Copings Using Different Resin Cements
Statement of the Problem: For a successful clinical outcome, luting agents should have a high bond strength. Bond failure is still one of the main reasons of restoration failures. Purpose: The present study was designed to comparatively evaluate the retention of metallic copings using different resin luting cements. Materials and Method: In the present experimental study, 40 intact premolar tee...
متن کاملComparative Evaluation of Dentinal Microcrack Incidence After Root Canal Preparation by BioRaCe and Edge Taper Platinum
Background and Aim: Preparation of root canal with rotary nickel-titanium (NiTi) instruments may potentially create microcracks that can lead to vertical root fracture. This study aimed to compare the incidence of crack formation by BioRaCe and Edge Taper Platinum systems in the mesiobuccal canals of extracted first mandibular molars. Materials and Methods: In this experimental study, 50 first...
متن کاملIn vitro evaluation of three techniques to obturate 0.06 taper canal preparations.
The aim of this study was to evaluate the ability of three obturation methods to seal root canals prepared using 0.06 taper rotary instruments. Forty-five extracted human single-rooted teeth were instrumented with 0.06 taper Profile nickel-titanium rotary files and randomly divided into three experimental groups containing 15 teeth each. The first group was obturated using the System B techniqu...
متن کاملQuantitative Assessment of apically Extruded Bacteria using different Instrumentation Techniques and Preparation Taper.
BACKGROUND Cleaning and shaping of the pulp canal is one of the most important steps of endodontic therapy. Serious complications occur by the apical extrusion of bacteria during the instrumentation procedures. Both crown-down (CD) and full-length linear motion (FM) techniques are routinely used as a component of taper rotary instrument procedures for achievement of thorough cleaning and shapin...
متن کاملThe taper of cast post preparation measured using innovative image processing technique
BACKGROUND No documentation in the literature about taper of cast posts. This study was conducted to measure the degree of cast posts taper, and to evaluate its suitability based on the anatomy aspects of the common candidate teeth for post reconstruction. METHODS Working casts for cast posts, prepared using Gates Glidden drills, were collected. Impressions of post spaces were made using poly...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of oral science
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2005