A novel technique to estimate and model parameters of a 460-MVA large steam turbine generator from operating data is presented. First, data from small excitation disturbances are used to estimate linear model armature circuit and field winding parameters of the machine. Subsequently, for each set of steady state operating data, saturable inductances and are identified and modeled using nonlinear mapping functions-based estimators. Using the estimates of the armature circuit parameters, for each set of disturbance data collected at different operating conditions, the rotor body parameters of the generator are estimated using an output error method (OEM). The developed nonlinear models are validated with measurements not used in the estimation procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Online State Space Model Parameter Estimation in Synchronous Machines

The purpose of this paper is to present a new approach based on the Least Squares Error method for estimating the unknown parameters of the nonlinear 3rd order synchronous generator model. The proposed method uses the mathematical relationships between the machine parameters and on-line input/output measurements to estimate the parameters of the nonlinear state space model. The field voltage is...

متن کامل

تخمین پارامترهای مدل کلاسیک ژنراتور با استفاده از داده های PMU

Parameters estimation of dynamic model of synchronous generators is an essential prerequisite for viable and reliable power system operation and offline studies. Advent of phasor measurement units (PMU) and its growing applications in power systems have led to an evolution in the electric power network wide-area monitoring, protection, and control. Alongside, these devices have revealed unprece...

متن کامل

Investigation of STATCOM effects on synchronous generator impedance based LOF relay with considering a realistic model for the excitation system of the generator

This paper studies the effects of static synchronous compensator (STATCOM) on synchronous generator conventional loss of field (LOF) protection. To accomplish a comprehensive study, a typical and realistic excitation system is considered for the generator by using the phase-domain generator model available in the real-time-digital-simulator. Using such a system, LOF phenomenon is realistically ...

متن کامل

Influence of Saturation on On-line Estimation of Synchronous Generator Parameters

This paper discusses on-line estimation of rotor body parameters of the synchronous hydro-generator under saturated condition. A new model of the saturated synchronous salient-pole machine, based on the saturated synchronous inductances which are estimated from measured steady-state operating data, is presented. Using this model the excitation disturbance responses of the saturated synchronous ...

متن کامل

Identification of Synchronous Generator Parameters Using Continuous ARX Model and Least Square Estimation

In this paper, least square estimation (LSE)-based synchronous generator model identification is carried out. The synchronous generator model including electromechanical dynamics and primary frequency control is first expressed by continuous-time AutoRegressive with eXogenous (ARX) models. The high-order derivatives in a continuous ARX model are approximated by expressions in terms of discrete-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001