Patient-specific instrumentation does not improve accuracy in total knee arthroplasty.
نویسندگان
چکیده
Patient-specific instrumentation (PSI) has been introduced as a tool to increase the accuracy of total knee arthroplasty (TKA) compared with conventional instrumentation (CLI). However, previous studies have shown inconsistent results. The authors conducted a meta-analysis to compare the performance of PSI to CLI in TKA. PubMed, EMBASE, and Cochrane Central Register of Controlled Trials electronic databases were systematically searched to identify eligible trials published between 2000 and March 2014. Two reviewers independently assessed methodological quality according to the Cochrane Handbook. Subgroup analyses were performed based on the different study designs (randomized, controlled trial [RCT] vs non-randomized, controlled trial [non-RCT]), preoperative magnetic resonance imaging vs computed tomography, and systems of PSI to explore the source of heterogeneity. Fourteen studies (7 RCTs and 7 non-RCTs) involving 1906 patients were included. There were no statistical differences with respect to the outliers of mechanical axis, coronal femoral component, sagittal femoral component, femoral component rotation, operative time, blood loss, and length of hospital stay between PSI and CLI groups. The number of outliers in coronal tibial components (odds ratio, 2.29; 95% confidence interval, 1.20 to 4.35; P=.01) and sagittal tibial components (odds ratio, 1.67; 95% confidence interval, 1.16 to 2.42; P<.01) was significantly lower in the CLI group than in the PSI group. Based on the numbers available, the use of PSI compared with CLI was not likely to improve the accuracy of component alignment and treatment effects of TKA. Further high-quality RCTs are warranted to confirm the authors' results.
منابع مشابه
Comparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملPatient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty
Background and purpose - Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. Patients and methods - We identified randomized and quasi-randomized...
متن کاملConservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience
Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...
متن کاملAccuracy of patient-specific instrumentation compared with conventional instrumentation in total knee arthroplasty.
Patient-specific instrumentation (PSI) has recently been introduced to improve the alignment following total knee arthroplasty (TKA). However, controversy remains between PSI and conventional instrumentation. The aim of this study is to compare the accuracy of PSI with conventional instruments for total knee arthroplasty (TKA). A systematic literature search was performed in databases including...
متن کاملPatient-specific instrumentation for total knee replacement verified by computer navigation: a case report.
Patient-specific instrumentation (PSI) enables better restoration of the mechanical axis in total knee replacement (TKR) than conventional instrumentation (alignment guides) does. We verified the accuracy of the PSI by computer navigation. The PSI jigs were accurate only if they were pinned accurately onto the distal femur and proximal tibia. Any slight malposition of the jigs leads to malalign...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Orthopedics
دوره 38 3 شماره
صفحات -
تاریخ انتشار 2015