Comparison of lung deposition in two types of nebulization: intrapulmonary percussive ventilation vs jet nebulization.
نویسندگان
چکیده
BACKGROUND So-called intrapulmonary percussive ventilation (IPV), frequently coupled with a nebulizer, is increasingly used as a physiotherapy technique; however, its physiologic and clinical values have not been rigorously assessed. STUDY OBJECTIVE To compare in vitro and in vivo characteristics of the nebulizer of the IPV device (Percussionaire; Percussionaire Corporation; Sandpoint, ID) with those of standard jet nebulization (SST) [SideStream; Medic-Aid; West Sussex, UK]. DESIGN Aerodynamic particle size was studied by an cascade impactor. The deposition of (99m)Tc-diethylenetriaminepenta-acetic acid was measured in 10 healthy subjects by tomoscintigraphy during spontaneous breathing with both nebulizers. MEASUREMENTS AND RESULTS The mass median aerodynamic diameter (0.2 micro m vs 1.89 micro m for IPV and SST, respectively) and the fine-particle fraction (16.2% vs 67.5%, respectively) were significantly smaller with IPV. In vivo, respiratory frequency (RF) was lower with the IPV device (10.1 +/- 3.4 breaths/min vs 14.6 +/- 3.4 breaths/min, p = 0.002). Whole-body deposition was significantly higher with IPV (15.63% vs 9.31%), but it was due to a higher extrapulmonary deposition. Although intrapulmonary deposition (IPD) was not different with both devices (4.20% for SST vs 2.49% for IPV), it was much more variable with IPV, compared to SST. The penetration index into the lung was higher with IPV than SST when normalized for RF (0.045 +/- 0.018 breaths/min vs 0.026 +/- 0.013 breaths/min, p = 0.007). CONCLUSION The two techniques showed comparable lung deposition despite a large difference in particle size. However, IPV IPD was too variable and thus too unpredictable to recommend its use for drug delivery to the lung.
منابع مشابه
Comparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.
Increased delivery of aerosol to a model lung (attached to a mechanical ventilator) has been demonstrated with an ultrasonic nebulizer as compared to a jet nebulizer. This study examined whether the increased aerosol deposition with an ultrasonic nebulizer could also be demonstrated in vivo. Seven patients (6 male and 1 female) were studied during mechanical ventilalion (Siemens Servo 900C, Mid...
متن کاملAlbuterol delivery in an in vitro pediatric ventilator lung model: comparison of jet, ultrasonic, and mesh nebulizers.
OBJECTIVE To determine the influence of nebulizer types and nebulization modes on bronchodilator delivery in a mechanically ventilated pediatric lung model. DESIGN In vitro, laboratory study. SETTING Research laboratory of a university hospital. INTERVENTIONS Using albuterol as a marker, three nebulizer types (jet nebulizer, ultrasonic nebulizer, and vibrating-mesh nebulizer) were tested ...
متن کاملEffect of drug targeting nebulization on lung deposition: a randomized crossover scintigraphic comparison between central and peripheral delivery.
BACKGROUND Recent technological advances in nebulization permit researchers to target specific parts of the lungs by modifying delivery method. The aim of this study was to compare the central and peripheral targeted modalities of administration. METHODS Lung and regional deposition of inhaled technetium-99m diethylene triamine penta-acetic was measured by scintigraphy after peripheral and ce...
متن کاملVentilator-integrated jet nebulization systems: tidal volume control and efficiency of synchronization.
BACKGROUND Jet nebulizers constitute the aerosolization devices most frequently used during mechanical ventilation. Continuous nebulization can influence the delivered tidal volume (V(T)) and lead to significant medication loss during expiration. Ventilators thus provide integrated jet nebulization systems that are synchronized during inspiration and ostensibly keep VT constant. METHODS This ...
متن کاملNoninvasive ventilation coupled with nebulization during asthma crises: a randomized controlled trial.
BACKGROUND Despite the clinical improvements attributed to noninvasive ventilation (NIV) during asthma crises, and the well established effects of nebulization, there are few studies on the effects of these interventions together. We hypothesized that nebulization coupled to NIV should raise radio-aerosol pulmonary deposition in asthmatics. The aims of this study were to assess the effects of c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 125 2 شماره
صفحات -
تاریخ انتشار 2004