Optical Coherence Tomography Enabling Non Destructive Metrology of Layered Polymeric GRIN Material

نویسندگان

  • Panomsak Meemon
  • Jianing Yao
  • Kye-Sung Lee
  • Kevin P. Thompson
  • Michael Ponting
  • Eric Baer
  • Jannick P. Rolland
چکیده

Gradient Refractive INdex (GRIN) optical components have historically fallen short of theoretical expectations. A recent breakthrough is the manufacturing of nanolayered spherical GRIN (S-GRIN) polymer optical elements, where the constructionmethod yields refractive index gradients that exceed 0.08. Here we report on the application of optical coherence tomography (OCT), includingmicron-class axial and lateral resolution advances, as effective, innovative methods for performing nondestructive diagnostic metrology on S-GRIN. We show that OCT can be used to visualize and quantify characteristics of the material throughout the manufacturing process. Specifically, internal film structure may be revealed and data are processed to extract sub-surface profiles of each internal film of the material to quantify 3D film thickness and homogeneity. The technique provides direct feedback into the fabrication process directed at optimizing the quality of the nanolayered S-GRIN polymer optical components.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-destructive Inspection of Anti-corrosion Protective Coatings Using Optical Coherent Tomography

Optical Coherence Tomography (OCT) is one of the most rapidly advancing techniques. This method is capable of non-contact and non-destructive investigation of the inner structure of a broad range of materials. Compared with other methods which belong to the NDE/NDT group (Non-Destructive Evaluation/Non-Destructive Testing methods), OCT is capable of a broad range of scattering material structur...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Three-dimensional non-destructive optical evaluation of laser-processing performance using optical coherence tomography.

We demonstrate the use of optical coherence tomography (OCT) as a non-destructive diagnostic tool for evaluating laser-processing performance by imaging the features of a pit and a rim. A pit formed on a material at different laser-processing conditions is imaged using both a conventional scanning electron microscope (SEM) and OCT. Then using corresponding images, the geometrical characteristic...

متن کامل

GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking.

In this manuscript, a GRIN (gradient index) lens rod based probe for endoscopic spectral domain optical coherence tomography (OCT) with dynamic focus tracking is presented. Current endoscopic OCT systems have a fixed focal plane or working distance. In contrast, the focus of this endoscopic OCT probe can dynamically be adjusted at a high speed (500 mm/s) without changing reference arm length to...

متن کامل

Optical Coherence Tomography – Applications in Non-Destructive Testing and Evaluation

The field of non-destructive testing and evaluation (NDTE) comprises many different techniques and approaches. Over the past few decades there have been tremendous ad‐ vances in NDTE technology, allowing researchers and engineers to tackle problems in many scientific and industrial fields. However, techniques enabling a fast, contactless, non-invasive, and high-resolution imaging of subsurface ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013