A simple and precise method for quantitative analysis of lumefantrine by planar chromatography
نویسندگان
چکیده
A simple, precise and sensitive high performance thin layer chromatographic (HPTLC) method has been developed and validated for drug of choice Lumefantrine in treatment of malaria (P. falciparum). Silica gel 60 F254 HPTLC precoated plates were used for quantitative analytical purpose. Methanol water 9.5 + 0.5 (v/v) was used as the solvent system. Densitometric scanning was carried out with deuterium lamp set at detection wavelength of 266 nm. The response to lumefantrine concentration was linear in the concentration range of 1.25-12.50 μg/ml. The suitability of the method developed and validated was in accordance with the requirements of the ICH guidelines (Q2B). Thus the validated method can be further applied to quantitative analysis of lumefantrine in commercial pharmaceutical dosage form. The proposed method is simple, sensitive, precise and accurate, confirming its pharmaceutical application in routine quality control analysis.
منابع مشابه
Quantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملUltrasound Assisted Emulsification Microextraction as a Simple Preconcentration Method for Determination of Atrazine in Environmental Samples
We represent an environmentally friendly sample of pre-treatment method, ultrasound assisted emulsification microextraction (USAEME) followed by gas chromatography nitrogen phosphorous detector (GC-NPD), to specify atrazine residues in environmental samples. Some parameters affecting the extraction efficiency such as the type and volume of the extraction solvent, emulsification time and additio...
متن کاملA Validated Reverse Phase Hplc Method for the Simultaneous Estimation of Artemether and Lumefantrine in Pharmaceutical Dosage Forms
A simple, sensitive and precise reverse phase high performance liquid chromatographic method has been developed for the simultaneous estimation of Artemether and Lumefantrine in pharmaceutical dosage forms. The mobile phase consisted of Acetonitrile: buffer (0.1% v/v ortho phosphoric acid, PH – 3) in the ratio of 60:40 v/v delivered at a flow rate of 1.5 ml / min and wavelength of detection at ...
متن کامل