Screening for refractive errors in children: accuracy of the hand held refractor Retinomax to screen for astigmatism.
نویسندگان
چکیده
AIMS To assess the reliability of the hand held automated refractor Retinomax in measuring astigmatism in non-cycloplegic conditions. To assess the accuracy of Retinomax in diagnosing abnormal astigmatism in non-cycloplegic refractive screening of children between 9 and 36 months. METHODS Among 1205 children undergoing a non-cycloplegic refractive screening with Retinomax, 299 (25%) had repeated non-cycloplegic measurements, 302 (25%) were refracted under cycloplegia using the same refractor, and 88 (7%) using retinoscopy or an automated on table refractor. The reproducibility of non-cycloplegic cylinder measurement was assessed by comparing the cylindrical power and axis values in the 299 repeated measurements without cycloplegia. The influence of the quick mode on cylinder measurement was analysed by comparing the cylinder and axis value in 93 repeated measurements without cycloplegia where normal mode was used in one measurement and quick mode in the other. Predictive values of the refractive screening were calculated for three different thresholds of manifest astigmatism (> or = 1.5, > or = 1.75, and > or = 2 D) considering as a true positive case an astigmatism > or = 2 D under cycloplegic condition (measured by retinoscopy, on table, or hand held refractor). RESULTS The 95% limits of agreement between two repeated manifest cylinder measurements with Retinomax attained levels slightly less than plus or minus 1 D. The 95% limits of agreement for the axis were plus or minus 46 degrees. The comparison of non-cycloplegic measurements in the quick and normal mode showed no significant difference and 95% limits of agreement plus or minus 0.75 D. The mean difference between non-cycloplegic and cycloplegic cylinder values measured by Retinomax reached 0.17 D and was statistically significant. Manifest thresholds of > or = 1.5 D, > or = 1.75 D, > or = 2 D cylinder value diagnosed 2 D of astigmatism under cyclplegia respectively with 71-84%, 59-80%, 51-54% of sensitivity (right eye-left eye) and 90-92%, 95%, 98% of specificity. CONCLUSION Without cycloplegia, Retinomax is able to measure cylinder power with the same reproducibility as cycloplegic retinoscopy. No significant difference was found in the cylinder values obtained with the quick and the normal modes. Therefore, the quick mode of measurement is recommended as it is more feasible in children. No difference, which is significant from a screening point of view, exists between the non-cycloplegic and the cycloplegic cylinder value (< 0.25 D). Retinomax diagnoses abnormal astigmatism (> or = 2 D) in a non-cycloplegic refractive screening at preschool ages with 51-84% sensitivity rates and 98-90% specificity rates, depending on the chosen threshold of manifest astigmatism. If 2 D of manifest astigmatism is chosen as a positive test, the positive predictive value of the screening reaches 81-84% and the negative predictive value 91-90% (right eye-left eye).
منابع مشابه
Screening for abnormal levels of hyperopia in children: a non-cycloplegic method with a hand held refractor.
AIMS High hyperopia constitutes the majority of refractive errors in large scale visual screening at preschool ages. The authors aimed to assess the validity of the Retinomax hand held refractor to detect high hyperopia in a refractive screening performed without cycloplegia and carried out on children aged 9-36 months. They considered +1.5 D of manifest hyperopia to be the threshold value and ...
متن کاملNon-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children.
AIMS To assess non-cycloplegic screening for amblyopia with the hand held Nikon Retinomax autorefractor in 3 year old kindergarten children. METHODS 427 three year old children were examined in kindergarten with the Retinomax without cycloplegia. A gold standard was established in all children by two orthoptic examinations in kindergarten. If there were missing, abnormal, or inconsistent find...
متن کاملReproducibility and accuracy of measurements with a hand held autorefractor in children.
AIM To determine reproducibility and accuracy of the Nikon Retinomax autorefractor when used with children who were made cycloplegic. METHODS Autorefraction and retinoscopy or subjectively refined retinoscopy (where, under the patient's direction, the refraction was varied until the best visual acuity was achieved) were performed on the right eye of 47 children, age 11-93 months. Autorefracti...
متن کاملAccuracy of noncycloplegic retinoscopy, retinomax autorefractor, and SureSight vision screener for detecting significant refractive errors.
PURPOSE To evaluate, by receiver operating characteristic (ROC) analysis, the ability of noncycloplegic retinoscopy (NCR), Retinomax Autorefractor (Retinomax), and SureSight Vision Screener (SureSight) to detect significant refractive errors (RE) among preschoolers. METHODS Refraction results of eye care professionals using NCR, Retinomax, and SureSight (n = 2588) and of nurse and lay screene...
متن کاملComparison of the Refractive Measurements with Hand-held Autorefractometer, Table-mounted Autorefractometer and Cycloplegic Retinoscopy in Children
PURPOSE To evaluate the performance of the hand-held and table-top autorefractokeratometer in measuring refractive errors by comparing them with cycloplegic retinoscopy. METHODS Included in the study were 112 eyes of 112 pediatric patients whose mean age was 6.78 ± 2.61 years (range, 2 to 12 years). The refractive errors of all the eyes were measured with and without cycloplegia using a hand ...