Multigating, a 4D Optimized Beam Tracking in Scanned Ion Beam Therapy
نویسندگان
چکیده
The treatment of moving tumors with a scanned ion beam is challenging due to interplay effects and changing beam range. We propose multigating, as a method for 4D-treatment optimization and delivery. In 3D beam tracking, tracking vectors are added during delivery to beam spot positions based on the detected motion phase. This has the disadvantage of dose errors in case of complex motion patterns and an uncertain out-of-target dose distribution. In multigating, the motion phase for each beam spot is predefined, which allows to add the tracking vector prior to beam weight optimization on all motion phases. The synchronization of delivery and target motion is assured by fast gating. The feasibility of the delivery was shown in a film experiment and required only minor software modification to the treatment planning system. In a treatment planning study in 4 lung cancer patients, target coverage could be restored to the level of a static reference plan by multigating (V95 > 99%) but not by standard beam tracking (V95 < 95%). The conformity of the multigating plans was only slightly lower than those of the static plan, with a conformity number of 72.0% (median, range 64.6-76.6%) compared to 75.8% (70.8-81.5%) in spite of target motion of up to 22 mm. In conclusion, we showed the technical feasibility of multigating, a 4D-optimization and delivery method using scanned beams that allows for conformal and homogeneous dose delivery to moving targets also in case of complex motion.
منابع مشابه
4D optimization of scanned ion beam tracking therapy for moving tumors.
Motion mitigation strategies are needed to fully realize the theoretical advantages of scanned ion beam therapy for patients with moving tumors. The purpose of this study was to determine whether a new four-dimensional (4D) optimization approach for scanned-ion-beam tracking could reduce dose to avoidance volumes near a moving target while maintaining target dose coverage, compared to an existi...
متن کامل4D treatment planning for scanned ion beams
At Gesellschaft für Schwerionenforschung (GSI) more than 330 patients have been treated with scanned carbon ion beams in a pilot project. To date, only stationary tumors have been treated. In the presence of motion, scanned ion beam therapy is not yet possible because of interplay effects between scanned beam and target motion which can cause severe mis-dosage. We have started a project to trea...
متن کاملManagement of organ motion in scanned ion beam therapy
Scanned ion beam therapy has special demands for treatment of intra-fractionally moving tumors such as lesions in lung or liver. Interplay effects between beam and organ motion can in those settings lead to under-dosage of the target volume. Dedicated treatment techniques such as gating or abdominal compression are required. In addition 4D treatment planning should be used to determine strategi...
متن کاملRefined method for calculation of compensation parameters
Irradiations of intra-fractionally moving organs with a scanned ion beam need to be performed with a dedicated motion mitigation technique to avoid cold-spots in the delivered dose distribution due to interplay [1]. One possible way to achieve this is beam tracking [2]. Beam tracking compensates organ motion by adjusting the position of the pencil beam in real-time during treatment delivery. Th...
متن کامل4D in-beam PET of moving targets for different irradiation scenarios
Introduction Ion therapy allows a high precision, tumor conformal dose application but it is very sensitive to density changes along the beam path. Intra-fractional tumor motion due to respiration increases the risk of an incorrect irradiation and thus requires a reliable dosimetry as it was done by means of 3D in-beam PET for more than 400 patients at the experimental heavy ion treatment facil...