Multi-centre assessment of the Spiegelberg compliance monitor: preliminary results.

نویسندگان

  • I Piper
  • L Dunn
  • C Contant
  • Y Yau
  • I Whittle
  • G Citerio
  • K Kiening
  • W Schvning
  • S Ng
  • W Poon
  • P Enblad
  • P Nilsson
چکیده

Acute brain injury states (e.g. head injury, subarachnoid haemorrhage) show clear inverse relationships of ICP vs compliance, with ICP instability at times of lower compliance states. Variance in compliance values is large in hydrocephalus where ICP is relatively lower and compliance higher. Nonetheless, early experience shows that compliance data influence decisions on CSF diversion treatments. Future work will focus on the ability of intracranial compliance to predict ensuing ICP instability and methodological refinement for monitoring patients who have higher compliance states.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental evaluation of the Spiegelberg intracranial pressure and intracranial compliance monitor. Technical note.

The goal of this study was to compare the Spiegelberg intraventricular intracranial pressure (ICP)/intracranial compliance monitoring device, which features an air-pouch balloon catheter, with existing gold-standard methods of measuring ICP and intracranial compliance. A Spiegelberg intraventricular catheter, a standard intraventricular catheter, and a Codman intraparenchymal ICP microsensor we...

متن کامل

Laboratory testing of the Spiegelberg brain pressure monitor: a technical report.

OBJECTIVES The Spiegelberg brain pressure monitor is a low cost intracranial pressure monitoring system that has been used clinically for some time, mainly in Germany. To provide a rigorous bench comparison of the Spiegelberg monitor with the Camino pressure monitor an evaluation programme has been carried out in the UK Shunt Evaluation Laboratory. DESIGN Drift over 72 hours and with temperat...

متن کامل

Professionalism Mini-Evaluation Exercise in Finland: a preliminary investigation introducing the Finnish version of the P-MEX instrument

Introduction: Teaching medical professionalism is increasinglyacknowledged as an important aspect of medical education.The Professionalism Mini-Evaluation Exercise (P-MEX) is anassessment tool for evaluating medical professionalism, butno studies using it as a self-assessment instrument have beenreported. This paper reports on a preliminary investigation of theFinnish version of the P-MEX instr...

متن کامل

Exposure assessment of the radon in residential tap water in Kastamonu

Background: It is considered that if radon gas is inhaled and ingested, it is the primary health risks for lung and stomach cancers. This paper presents the measurement results of radon activity concentrations both residential tap water and dam water for Kastamonu city Centre-Turkey. Materials and Methods: The radon activity concentrations of water samples collected from 60 tap waters at four l...

متن کامل

Does Mesenchymal Stem Cell Therapy Help Multiple Sclerosis Patients? Report of a Pilot Study

Background: Mesenchymal stem cells (MSCs) with their potential to differentiate into mesodermal and non-mesodermal lineages have several immunomodulatory characteris-tics. These properties make them promising tools in cell and gene therapy. Objective: To evaluate the potential therapeutic applications of autologous MSC in improving clinical manifestations of MS patients. Methods: Ten patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta neurochirurgica. Supplement

دوره 76  شماره 

صفحات  -

تاریخ انتشار 2000