Safety and Efficacy of Left Atrial Appendage Closure with the Amplatzer Cardiac Plug in Very High Stroke and Bleeding Risk Patients with Non-Valvular Atrial Fibrillation
نویسندگان
چکیده
INTRODUCTION Limited data exist on the outcomes after left atrial appendage closure (LAAC) with the Amplatzer™ Cardiac Plug (ACP; St. Jude Medical, Minneapolis, MN, USA) in patients with atrial fibrillation (AF) with very high stroke and bleeding risks, the subset expected to benefit most from this procedure. The objective of this study was to report clinical outcomes after LAAC with the ACP device in a very high stroke and bleeding risk cohort of patients with non-valvular AF and contraindications to oral anticoagulation (OAC). METHODS LAAC using the ACP device was performed in 96 patients with AF who had median CHA2DS2-VASc and HAS-BLED scores of 5 and 3, respectively. Post-procedure, patients received dual antiplatelet therapy for 6 months. A transesophageal echocardiography (TEE) was scheduled at 6 months. RESULTS Procedural success was 100%. Procedural-related complications occurred in 7.3% (pericardial effusion, 4.2%; thromboembolic events, 2.1%; device embolization, 1.0%). Additional thromboembolic events occurred in three patients during follow-up (92.7% follow-up). After 93.4 patient-years of follow-up, the annual rates of thromboembolic and major bleeding events were 3.2% and 1.1%, respectively. In those with TEE follow-up (70%), complete LAAC with no leaks was observed. Thrombus formation on the device was noted on TEE in two patients. CONCLUSION LAAC using the ACP device was associated with an acceptable low rate of embolic and bleeding events after a median follow-up of 9 months in a cohort of patients with AF who were amongst the highest stroke and bleeding risks reported so far in LAAC trials.
منابع مشابه
Percutaneous closure of the left atrial appendage using the Amplatzer Cardiac Plug in patients with atrial fibrillation: evaluation of safety and feasibility.
BACKGROUND Ischaemic stroke is a common complication of atrial fibrillation (AF). Cardiology societies recommend assessing the risk of ischaemic stroke and using adequate prevention in patients with AF. Currently, oral anticoagulants and antiplatelet drugs are the most commonly used methods of stroke prevention. Left atrial appendage (LAA) is thought to be the main source of thrombi in patients...
متن کاملLeft Atrial Appendage Closure with Amplatzer Cardiac Plug in Nonvalvular Atrial Fibrillation: Safety and Long-Term Outcome
BACKGROUND Atrial fibrillation (AF) is a cardiac arrhythmia with high risk for thromboembolic events, specially stroke. OBJECTIVE To assess the safety of left atrial appendage closure (LAAC) with the Amplatzer Cardiac Plug for the prevention of thromboembolic events in patients with nonvalvular AF. METHODS This study included 15 patients with nonvalvular AF referred for LAAC, 6 older than 7...
متن کاملCardiac Plug I and Amulet Devices: Left Atrial Appendage Closure for Stroke Prophylaxis in Atrial Fibrillation.
Percutaneous left atrial appendage (LAA) occlusion has emerged as an exciting and effective modality for stroke prophylaxis in patients with non-valvular atrial fibrillation who are deemed too high risk for anticoagulation with warfarin or newer anticoagulants. The Amplatzer devices have been used in LAA occlusion for more than a decade, starting with off label use of an atrial septal occluder ...
متن کاملPercutaneous occlusion of left atrial appendage with the Amplatzer Cardiac PlugTM in atrial fibrillation.
BACKGROUND Atrial fibrillation is associated with embolic strokes that often result in death or disability. Effective in reducing these events, anticoagulation has several limitations and has been widely underutilized. Over 90% of thrombi identified in patients with atrial fibrillation without valvular disease originate in the left atrial appendage, whose occlusion is investigated as an alterna...
متن کاملPercutaneous Left Atrial Appendage€Closure
Ma Percutaneous left atrial appendage closure technology for stroke prevention in patients with atrial fibrillation has significantly advanced in the past 2 decades. Several devices are under clinical investigation, and a few have already received Conformité Européene (CE)-mark approval and are available in many countries. The WATCHMAN device (Boston Scientific, Natick, Massachusetts) has the m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2015