Gradient static-strain stimulation in a microfluidic chip for 3D cellular alignment.

نویسندگان

  • Hsin-Yi Hsieh
  • Gulden Camci-Unal
  • Tsu-Wei Huang
  • Ronglih Liao
  • Tsung-Ju Chen
  • Arghya Paul
  • Fan-Gang Tseng
  • Ali Khademhosseini
چکیده

Cell alignment is a critical factor to govern cellular behavior and function for various tissue engineering applications ranging from cardiac to neural regeneration. In addition to physical geometry, strain is a crucial parameter to manipulate cellular alignment for functional tissue formation. In this paper, we introduce a simple approach to generate a range of gradient static strains without external mechanical control for the stimulation of cellular behavior within 3D biomimetic hydrogel microenvironments. A glass-supported microfluidic chip with a convex flexible polydimethylsiloxane (PDMS) membrane on the top was employed for loading the cells suspended in a prepolymer solution. Following UV crosslinking through a photomask with a concentric circular pattern, the cell-laden hydrogels were formed in a height gradient from the center (maximum) to the boundary (minimum). When the convex PDMS membrane retracted back to a flat surface, it applied compressive gradient forces on the cell-laden hydrogels. The concentric circular hydrogel patterns confined the direction of hydrogel elongation, and the compressive strain on the hydrogel therefore resulted in elongation stretch in the radial direction to guide cell alignment. NIH3T3 cells were cultured in the chip for 3 days with compressive strains that varied from ~65% (center) to ~15% (boundary) on hydrogels. We found that the hydrogel geometry dominated the cell alignment near the outside boundary, where cells aligned along the circular direction, and the compressive strain dominated the cell alignment near the center, where cells aligned radially. This study developed a new and simple approach to facilitate cellular alignment based on hydrogel geometry and strain stimulation for tissue engineering applications. This platform offers unique advantages and is significantly different from the existing approaches owing to the fact that gradient generation was accomplished in a miniature device without using an external mechanical source.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A microfluidic 3D hepatocyte chip for drug toxicity testing.

We have developed a microfluidic 3D hepatocyte chip (3D HepaTox Chip) for in vitro drug toxicity testing to predict in vivo drug hepatotoxicity. The 3D HepaTox Chip is based on multiplexed microfluidic channels where a 3D microenvironment is engineered in each channel to maintain the hepatocytes' synthetic and metabolic functions. The multiplexed channels allow for simultaneous administration o...

متن کامل

A microfluidic flow-stretch chip for investigating blood vessel biomechanics.

This microfluidic flow-stretch chip integrates fluid shear stress (FSS) and cyclic stretch (CS), two major mechanical stimulations in cardiovascular systems, for cultured cells. The model chip can deliver FSS and CS simultaneously or independently to vascular cells to mimic the haemodynamic microenvironment of blood vessels in vivo. By imposing FSS-only, CS-only, and FSS+CS stimulation on rat m...

متن کامل

Fit-to-Flow (F2F) interconnects: universal reversible adhesive-free microfluidic adaptors for lab-on-a-chip systems.

World-to-chip (macro-to-micro) interface continues to be one of the most complicated, ineffective, and unreliable components in the development of emerging lab-on-a-chip systems involving integrated microfluidic operations. A number of irreversible (e.g., adhesive gluing) and reversible techniques (e.g., press fitting) have attempted to provide dedicated fluidic passage from standard tubing to ...

متن کامل

A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis.

We have developed a prototype three-channel microfluidic chip that is capable of generating a linear concentration gradient within a microfluidic channel and is useful in the study of bacterial chemotaxis. The linear chemical gradient is established by diffusing a chemical through a porous membrane located in the side wall of the channel and can be established without through-flow in the channe...

متن کامل

A novel microfluidic platform with stable concentration gradient for on chip cell culture and screening assays.

In this work a novel microfluidic platform for cell culture and assay is developed. On the chip a static cell culture region is coupled with dynamic fluidic nutrition supply structures. The cell culture unit has a sandwich structure with liquid channels on the top, the cell culture reservoir in the middle and gas channels on the bottom. Samples can be easily loaded into the reservoir and exchan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2014