Sample Size Determination for Individual Bioequivalence Inference
نویسندگان
چکیده
Statistical criterion for evaluation of individual bioequivalence (IBE) between generic and innovative products often involves a function of the second moments of normal distributions. Under replicated crossover designs, the aggregate criterion for IBE proposed by the guidance of the U.S. Food and Drug Administration (FDA) contains the squared mean difference, variance of subject-by-formulation interaction, and the difference in within-subject variances between the generic and innovative products. The upper confidence bound for the linearized form of the criterion derived by the modified large sample (MLS) method is proposed in the 2001 U.S. FDA guidance as a testing procedure for evaluation of IBE. Due to the complexity of the power function for the criterion based on the second moments, literature on sample size determination for the inference of IBE is scarce. Under the two-sequence and four-period crossover design, we derive the asymptotic distribution of the upper confidence bound of the linearized criterion. Hence the asymptotic power can be derived for sample size determination for evaluation of IBE. Results of numerical studies are reported. Discussion of sample size determination for evaluation of IBE based on the aggregate criterion of the second moments in practical applications is provided.
منابع مشابه
Sample Size Determination from A Pilot Bioequivalence study for A Future Pivotal Bioequivalence Study: A SAS Procedure
The purpose of research study develops an automated computer statistical procedure to determine sample size from a pilot bioequivalence study for a future pivotal bioequivalence study. The sample size is critical in a pivotal bioavailability/ bioequivalence study, and was often estimated from a pilot study. A comprehensive review of current literature reveals that the software for sample size d...
متن کاملSample size determination for logistic regression
The problem of sample size estimation is important in medical applications, especially in cases of expensive measurements of immune biomarkers. This paper describes the problem of logistic regression analysis with the sample size determination algorithms, namely the methods of univariate statistics, logistics regression, cross-validation and Bayesian inference. The authors, treating the regr...
متن کاملBootstrap and MLS methods-based individual bioequivalence assessment
It is a one-sided hypothesis testing process for assessing bioequivalence. Bootstrap and modified large-sample(MLS) methods are considered to study individual bioequivalence(IBE), type I error and power of hypothesis tests are simulated and compared with FDA(2001). The results show that modified large-sample method is equivalent to the method of FDA(2001) . Keywords—individual bioequivalence; b...
متن کاملAssessing individual agreement.
Evaluating agreement between measurement methods or between observers is important in method comparison studies and in reliability studies. Often we are interested in whether a new method can replace an existing invasive or expensive method, or whether multiple methods or multiple observers can be used interchangeably. Ideally, interchangeability is established only if individual measurements f...
متن کاملSample size calculation for bioequivalence studies with high-order crossover designs.
Exact power and sample size calculation for bioequivalence studies with high order crossover designs using statistical software nQuery are presented. Such calculation can be very easily performed, and thus provides a convenient tool for practical usage.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014