Estimating positions of world points from features observed in images is a key problem in 3D reconstruction, image mosaicking, simultaneous localization and mapping and structure from motion. We consider a special instance in which there is a dominant ground plane G viewed from a parallel viewing plane S above it. Such instances commonly arise, for example, in aerial photography. Consider a world point g ∈ G and its worst case reconstruction uncertainty ε(g,S) obtained by merging all possible views of g chosen from S. We first show that one can pick two views sp and sq such that the uncertainty ε(g, {sp, sq}) obtained using only these two views is almost as good as (i.e. within a small constant factor of) ε(g,S). Next, we extend the result to the entire ground plane G and show that one can pick a small subset of S ′ ⊆ S (which grows only linearly with the area of G) and still obtain a constant factor approximation, for every point g ∈ G, to the minimum worst case estimate obtained by merging all views in S. Our results provide a view selection mechanism with provable performance guarantees which can drastically increase the speed of scene reconstruction algorithms. In addition to theoretical results, we demonstrate their effectiveness in an application where aerial imagery is used for monitoring farms and orchards.
منابع مشابه
Edge Artifacts in Point Spread Function-based PET Reconstruction in Relation to Object Size and Reconstruction Parameters
Objective(s): We evaluated edge artifacts in relation to phantom diameter and reconstruction parameters in point spread function (PSF)-based positron emission tomography (PET) image reconstruction.Methods: PET data were acquired from an original cone-shaped phantom filled with 18F solution (21.9 kBq/mL) for 10 min using a Biograph mCT scanner. The images were reconstructed using the baseline or...
متن کاملSubmental Artery Island Flap in Reconstruction of Harde Plate after wide Surgical Resection of Veruccous Carcinoma. Two case reports
Introduction: Reconstruction of intraoral soft tissue defects is important in restoring function and esthetic. In large defects, there will be demand for regional pedicle flaps or free flaps. Hard palate separates nasal and oral cavities. Due to the small surface area between flap and remaining palate after surgical resections, optimal blood supply of the flaps for hard palate reconstructions ...
متن کاملEvaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom
Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...
متن کاملUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures
Introduction:Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. Material and Methods:Sp...
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1704.00085 شماره
صفحات -
تاریخ انتشار 2010