Development of a high-throughput quantitative assay for detecting herpes simplex virus DNA in clinical samples.
نویسندگان
چکیده
We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 10(8) copies of HSV DNA/20 microl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.
منابع مشابه
Analysis of Herpes Simplex Virus in Suspected Encephalitis, Keratitis and Dermal Infections Using Real- Time PCR
Background & Objectives: Herpes viruses can cause diseases in the clinical range. The virus can cause infection in various body parts, especially eyes and nervous system. The aim of this study was at evaluating the Real-Time TaqMan probe PCR in diagnosing and monitoring of the patients with suspected HSV infections.Materials & Methods: More than a thousand patients with suspected HSV infection...
متن کاملDevelopment of a Western Blot Assay for Detection of Antibodies against HSV Using Purified HSV Virions Prepared by Sucrose Density Gradient
Objective(s) Herpes simplex viruses (HSVs) have widespread and ubiquitous prevalence in the human population and they have received a great deal of attention due to the range of diseases, they caused as a result of an infection. It seems that the fast and reliable diagnostic methods are needed for detecting the herpes simplex virus type 1 (HSV1) antibodies especially in patients with HSV encep...
متن کاملPrevalence of Herpes Simplex Virus type-1, 2 and Varicella Zoster Virus (VZV) in Eye Infection
Abstract Background and Aims: Herpes simplex virus (HSV) is a common cause of corneal disease and is the leading infectious cause of corneal blindness among developed nations. This study is aimed to provide an estimation of the incidence of Herpes Simplex Virustype-1, 2(HSV1, 2) and Varicella Zoster Virus (VZV) in tears and swab from eye infection by polymerase chain reaction (PCR) in eye ...
متن کاملLoop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملFrequency of Herpes simplex virus in patients with Stroke by PCR
Herpes simplex virus (HSV) causes a wide range of pathologies in the human central nervous system (CNS) such as stroke. It was proposed that there is an association between HSV infection and stroke with different results reported by the researchers using different methods. This study aimed to investigate the frequency of HSV among stroke patient and control groups. We detected HSV in 28 stroke ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of clinical microbiology
دوره 37 6 شماره
صفحات -
تاریخ انتشار 1999