Comparison of two x-ray phase-contrast imaging methods with a microfocus source.
نویسندگان
چکیده
We present a comparison for high-resolution imaging with a laboratory source between grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The comparison is done through simulations and experiments using a liquid-metal-jet x-ray microfocus source. Radiation doses required for detection in projection images are simulated as a function of the diameter of a cylindrical sample. Using monochromatic radiation, simulations show a lower dose requirement for PBI for small object features and a lower dose for GBI for larger object features. Using polychromatic radiation, such as that from a laboratory microfocus source, experiments and simulations show a lower dose requirement for PBI for a large range of feature sizes. Tested on a biological sample, GBI shows higher noise levels than PBI, but its advantage of quantitative refractive index reconstruction for multi-material samples becomes apparent.
منابع مشابه
Phase-contrast x-ray imaging with a liquid-metal-jet-anode microfocus source
Phase-contrast methods increase contrast, detail, and selectivity in x-ray imaging. Present compact x-ray sources do not provide the necessary spatial coherence with sufficient power to allow the laboratory-scale high-resolution phase-contrast imaging with adequate exposure times. In this letter, the authors demonstrate phase-contrast imaging with few-micron detail employing a compact 6.5 m spo...
متن کاملProcessing of projections containing phase contrast in laboratory micro-computerized tomography imaging
Free-space-propagation-based imaging belongs to several techniques for achieving phase contrast in the hard X-ray range. The basic precondition is to use an X-ray beam with a high degree of coherence. Although the best sources of coherent X-rays are synchrotrons, spatially coherent X-rays emitted from a sufficiently small spot of laboratory microfocus or sub-microfocus sources allow the transfe...
متن کاملFactors Affecting In-line Phase Contrast Imaging with a Laboratory Microfocus X-ray Source
An in-line method of phase contrast imaging is investigated using a polychromatic laboratorybased microfocus X-ray source. The effect of source size is considered, and by introducing water into the imaging path the influence of water on the phase contrast is determined. The results confirm that good phase contrast images can be achieved using a polychromatic laboratory-based X-ray source, and d...
متن کاملHigh-Resolution Differential Phase Contrast Imaging Using Microfocus X-Ray Sources
We combined grating-based phase contrast imaging with projection magnification using a high-brilliance microfocus x-ray source. This geometry offers increased detection efficiency even at higher energies for quantitative high-resolution phase contrast imaging. By systematic methodical investigations, it is shown, how the primary measurement signal is affected by the magnification factor. Furthe...
متن کاملInvestigation of the application of phase contrast imaging using a point X-ray source to industrial non-destructive testing.
X-Tek Systems, a division of Nikon Metrology UK, designs, develops and manufactures microfocus X-ray radiography and computed tomography systems for industrial non-destructive testing. The range of X-ray acceleration voltages of its current standard products is 130-450 kV. It is widely known that X-ray images can be created using phase contrast formed by the natural propagation of X-rays. Simul...