Fricke dosimetry for synchrotron stereotactic radiotherapy

نویسندگان

  • C Boudou
  • M C Biston
  • J F Adam
  • H Elleaume
چکیده

In synchrotron stereotactic radiotherapy (SSR) the tumor is loaded with a high Z element, and exposed to monochromatic x-rays from a synchrotron source, in stereotactic conditions. The SSR treatment efficiency is related to the heavy element concentration achievable in the tumor, to the radiation energy, and the irradiation geometry [1,2]. The experimental dose verification of SSR in three dimensions with a good spatial resolution is highly desirable for radiotherapy [3]. In this study, Fricke dosimeter and Monte Carlo calculations were employed for assessing 2D dose distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources

High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brac...

متن کامل

Design of an integral radiation dosimetry system optimized for modern medical applications

Fricke gel dosimetry is a valuable method for in-phantom dose measurements in complex irradiation modalities like IMRT and BNCT. Implementation of this dosimetry technique requires dedicated instruments capable of measuring and further analysis immediately in situ at the radiation facility. This work presents a novel and integral dosimetry system aimed to attain portability requirements. The me...

متن کامل

High-sensitivity radiation detector for low dose level radiological applications

Radiation dosimetry by Fricke gel was largely used, generally focused and optimized for radiotherapy applications therefore involving relative high dose levels. Fricke gel dosimetry has several advantages, like dose rate and LET almost independence, 3D mapping, among other. This work presents a novel Fricke gel dosimeter optimized for low dose levels. Several chemical composition were studied v...

متن کامل

Real‐time in vivo dosimetry for SBRT prostate treatment using plastic scintillating dosimetry embedded in a rectal balloon: a case study

A novel FDA approved in vivo dosimetry device system using plastic scintillating detectors placed in an endorectal balloon to provide real-time in vivo dosimetry for prostatic rectal interface was tested for use with stereotactic body radiotherapy (SBRT). The system was used for the first time ever to measure dose during linear accelerator based SBRT. A single patient was treated with a total d...

متن کامل

Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017