The P300 is sensitive to concealed face recognition.

نویسندگان

  • Ewout H Meijer
  • Fren T Y Smulders
  • Harald L G J Merckelbach
  • Ann G Wolf
چکیده

In two experiments, we investigated whether a P300 based Concealed Information Test (CIT) can be used to detect concealed face recognition. The results show that detection of concealed face recognition is highly successful when stimuli depict persons who are personally highly familiar, and instructions to conceal recognition are given. When pictures depict recognized, but personally less familiar faces, and no specific instructions to conceal recognition are given, detection is unsuccessful. These findings indicate that pictures of faces can be used in a P300 based CIT, and that mere recognition is not sufficient for successful detection of concealed information.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تشخیص و بررسی کاهش دامنۀ P300 در پتانسیل‌های وابسته به رویداد شنوایی تک‌ثبت با استفاده از الگوریتم ژنتیک و طبقه بندی‌کنندۀ شبکۀ عصبی

Abstract P300 is known as the most prominent component between cognitive components in electrical brain activity. According to done research, when brain encounters an inconsistent stimulation during processing a series of usual stimulation, a P300 component appears in recorded brain signal which could distinguishes from usual ones. Amplitude of P300 decreases after a short during act of auditor...

متن کامل

بازشناسی دانش فرد خطاکار به کمک سیگنال‌های تک ثبت مغزی، مبتنی بر روش غیرخطی منحنی‌های بازگشتی

In this study, Recurrence Plots (RPs) has been adapted as a nonlinear approach in order to detection of guilty subjects’ knowledge based on their single-trial ERPs. The dataset were acquired from 49 human subjects who were participated in a Concealed Information Test (CIT). According to the test protocol, guilty subjects denied their information about familiar faces, so the aim was to detect th...

متن کامل

P300 amplitudes in the concealed information test are less affected by depth of processing than electrodermal responses

The Concealed Information Test (CIT) has been used in the laboratory as well as in field applications to detect concealed crime related memories. The presentation of crime relevant details to guilty suspects has been shown to elicit enhanced N200 and P300 amplitudes of the event-related brain potentials (ERPs) as well as greater skin conductance responses (SCRs) as compared to neutral test item...

متن کامل

The Contribution of Mere Recognition to the P300 Effect in a Concealed Information Test

In two experiments, we investigated the role of mere recognition in a P300 based CIT. Mere recognition was isolated by having participants respond based on an irrelevant dimension of the stimuli. In Experiment 1 stimuli consisted of familiar and unfamiliar faces, with a dot placed on the left or the right cheek. Participants responded according to dot location. In the second experiment, partici...

متن کامل

The Complex Trial Protocol (CTP): a new, countermeasure-resistant, accurate, P300-based method for detection of concealed information.

A new P300-based concealed information test is described. A rare probe or frequent irrelevant stimulus appears in the same trial in which a target or nontarget later appears. One response follows the first stimulus and uses the same button press regardless of stimulus type. A later second stimulus then appears: target or nontarget. The subject presses one button for a target, another for a nont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of psychophysiology : official journal of the International Organization of Psychophysiology

دوره 66 3  شماره 

صفحات  -

تاریخ انتشار 2007