Thermosonic Testing with Phased Matched Guided Wave Excitation

نویسندگان

  • Markus RAHAMMER
  • Igor SOLODOV
  • Wolfgang BISLE
  • Dieter SCHERLING
  • Marc KREUTZBRUCK
چکیده

Vibrothermography, is an established NDT method praised for its fullfield and defect-selective imaging. Especially for cracks and similar damage, defect signals are produced within seconds for a wide variety of materials. Usually high power sonotrodes that are applied with kN pressure are employed in order to maximize ultrasonic excitation of the specimens. An increase in excitation power is used for boosting the defect signal strength, i.e. the rise in temperature. Improvements to the energy efficiency of the defect activation have been made by using local defect resonance (LDR). Via a frequency match of a defect’s resonance and the source’s driving frequency efficient pumping of the ultrasonic energy of guided waves to the defect is possible. As a consequence the use of simple, conventional excitation sources, e. g. piezo disc transducers, is viable while still achieving considerable enhancement in both vibration amplitude and temperature of the defect as well as signal-to-noise ratio of thermosonic images. However, due to the nature of most ultrasonic sources and their coupling methods to the specimen surface, the guided waves are usually radiated omnidirectionally from the source. Therefore, a significant fraction of the energy is radiated towards areas outside the infrared camera’s field of view. We present an innovative, patented coupling method that significantly improves the distribution of ultrasonic energy of guided waves within the specimen. It is possible to channel the energy towards a specified direction by placing periodic linear structures between the transducer and the specimen phase matched to the wavelength of the guided wave excited. The distance and the wavelength are determined by the excitation frequency and the specimen properties. This antennalike coupling device works exceptionally well in conjunction with the LDR technique, as both techniques require a frequency dependent setup. A significant increase in the defect vibration amplitude was measured when using this ultrasonic line source. Finally, thermosonic testing results confirm that channeling ultrasonic energy towards a specified direction is advantageous for exciting defect vibrations while using low energy input sources.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flaw Detection with Guided Waves Using Phased Array Technique

Guided waves travel in plates and hollow cylinders over large distances and propagate with multiple mode shapes. Therefore the waves can be used viably for integrity tests of large scale structures. The number of propagating modes increases with frequency. Due to their dispersive character the different modes are manageable only in a limited frequency range. Depending on the wave length and on ...

متن کامل

Recent Advances on Guided Waves in Pipe Inspection

Guided waves have been increasingly used in nondestructive evaluations. Guided waves have shown to be specially promising in the testing of pipelines and tubing systems due to the ability of propagating long distances. Recent advances on guided wave pipe inspection focus on the understanding and utilization of guided wave flexural modes. This paper discusses and compares the technologies curren...

متن کامل

Guided Wave Piezoelectric Wafer Active Sensor Arrays For Damage Detection

The paper describes an in-situ method for damage detection using phased arrays of piezoelectric wafers active sensors (PWAS) that are permanently attached to the structure. The method uses scanning beams of guided waves that can travel at large distances with little energy loss and hence permit the interrogation of large structural areas from a single location. The novelty of the present method...

متن کامل

Lamb Wave Dispersion Compensation in Piezoelectric Wafer Active Sensor Phased-Array Applications

Lamb-wave testing for structural health monitoring is complicated by the dispersion nature of the wave modes. The dispersion effect will result in a propagated wave with longer time duration, deformed envelop shape as compared to its excitation counterpart, and hard to be interpreted. This paper first reviews the dispersion compensation and removal algorithms. Second, it compares these two meth...

متن کامل

Phased-array Focusing with Longitudinal Guided Waves in a Viscoelastic Coated Hollow Cylinder

Guided wave phased-array focusing techniques have been studied and applied in the longrange guided wave inspection of industrial pipelines. Advantages include longer inspection distance, greater wave penetration power and higher detection sensitivity. For reasons of protection, safety and thermal efficiency, a large percentage of pipes are coated and/or encased and buried underground. A phased-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016