Evaluation of a diffusion charger for measuring aerosols in a workplace.
نویسندگان
چکیده
The model DC2000CE diffusion charger from EcoChem Analytics (League City, TX, USA) has the potential to be of considerable use to measure airborne surface area concentrations of nanoparticles in the workplace. The detection efficiency of the DC2000CE to reference instruments was determined with monodispersed spherical particles from 54 to 565.7 nm. Surface area concentrations measured by a DC2000CE were then compared to measured and detection efficiency adjusted reference surface area concentrations for polydispersed aerosols (propylene torch exhaust, incense, diesel exhaust, and Arizona road dust) over a range of particle sizes that may be encountered in a workplace. The ratio of surface area concentrations measured by the DC2000CE to that measured with the reference instruments for unimodal and multimodal aerosols ranged from 0.02 to 0.52. The ratios for detection efficiency adjusted unimodal and multimodal surface area concentrations were closer to unity (0.93-1.19) for aerosols where the majority of the surface area was within the size range of particles used to create the correction. A detection efficiency that includes the entire size range of the DC2000CE is needed before a calibration correction for the DC2000CE can be created. For diesel exhaust, the DC2000CE retained a linear response compared to reference instruments up to 2500 mm(2) m(-3), which was greater than the maximum range stated by the manufacturer (1000 mm(2) m(-3)). Physical limitations with regard to DC2000CE orientation, movement, and vibration were identified. Vibrating the DC2000CE while measuring aerosol concentrations may cause an increase of ~35 mm(2) m(-3), whereas moving the DC2000CE may cause concentrations to be inflated by as much as 400 mm(2) m(-3). Depending on the concentration of the aerosol of interest being measured, moving or vibrating a DC2000CE while measuring the aerosol should be avoided.
منابع مشابه
Use of direct-reading instruments for measuring airborne nanoparticles in the workplace
This work strived to increase knowledge of assessing airborne nanoparticles in the workplace by characterizing nanoparticle concentrations in a workplace using directreading instruments, evaluating a DC2000CE diffusion charger, and the creation of a personal diffusion battery (pDB). Direct-reading instruments were used with aerosol mapping and task monitoring to evaluate airborne nanoparticle c...
متن کاملDesign, construction and calibration of single channel sun-photometer for study of aerosols
Aerosols are tiny liquid or solid particles suspended in the air have a strong influence on air quality, human health and climate change. Sun-photometer is a tool for measuring the optical and physical characteristics of aerosols by using sunlight at various wavelengths from the Earth surface. In this paper, the design, construction, and calibration of a single channel sun-photometer is present...
متن کاملKnowledge Diffusion to Workplace Safety and Health Improvement
The purpose of this study is to develop a conceptual model of Workplace safety and Health Knowledge diffusion. As workplace safety is becoming a global issue in the competitiveness of the business environment, knowledge diffusion model to workplace safety is found a mandatory tool to create awareness of the society and conceptual model is developed. Literature review was conducted in collecting...
متن کاملAccurate Determination of Optimal Amount of Charger Capacitors for PHEVs
Nowadays, because of the need to decrease fuel consumption and greenhouse gas emissions and also their capability of exchanging power with the grid and regulating the frequency and voltage of the grid at different times of the day, electric vehicles are used more than before all across the world. It is highly important to pay attention to the efficiency, and decrease in the weight and volume of...
متن کاملExperimental Study of Charging Efficiencies and Losses of Submicron Aerosol Particles in a Cylindrical Tri-Axial Charger
The object of the present work was to design, construct and evaluate a cylindrical tri-axial charger for charging of submicron aerosol particles by unipolar ions. The corona discharge characteristics, the intrinsic and extrinsic particle charging efficiencies, and the losses of aerosol particles were experimentally evaluated for particle diameters in the range between 50 nm and 500 nm under dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Annals of occupational hygiene
دوره 58 4 شماره
صفحات -
تاریخ انتشار 2014