A reliable radiographic measurement for evaluation of normal distal tibiofibular syndesmosis: a multi-detector computed tomography study in adults

نویسندگان

  • Yanxi Chen
  • Minfei Qiang
  • Kun Zhang
  • Haobo Li
  • Hao Dai
چکیده

BACKGROUND Syndesmotic injury may be difficult to diagnose, and radiological evaluation is very important. The purpose of this study was to offer a series of reliable and repeatable normal tibiofibular syndesmosis parameters in diagnosing injuries of the syndesmosis. METHODS Multi-detector computed tomography (MDCT) and radiographs of the distal tibiofibular syndesmosis in 484 cases were retrospectively reviewed. Relevant parameters included the tibiofibular clear space (TCS), the tibiofibular overlap (TFO), the depth of the incisura fibularis (IFD), and the height of the incisura fibularis (IFH), which were measured by novel three-dimensional (3-D) and two-dimensional (2-D) techniques. The distance between the measuring plane of the distal tibiofibular syndesmosis and the tibial plafond was measured. Intra- and inter-rater reliability was assessed by intraclass correlation coefficient (ICC) and the root mean square standard deviation (RMS-SD), to determine measurement precision. Sex differences of parameters were analyzed using analysis of covariance (ANCOVA) with body height as the covariate. Paired sample t-testing was used to compare parameters in different image modalities, including radiography, and 2-D and 3-D CT. RESULTS The reliability of the 3-D images measurement (ICC range, 0.907 to 0.972) was greater than that for the 2-D axial images (ICC range, 0.895 to 0.927), and the AP view radiographs (ICC range, 0.742 to 0.838). The intra-rater RMS-SD of the 3-D CT, 2-D CT and radiographic measurements were less than 0.94 mm, 0.26 mm, and 2.87 mm, respectively. The measuring plane of the distal tibiofibular syndesmosis showed the sex difference, which was 12.1 mm proximal to the tibial plafond in the male group and 7.8 mm in the female group. In this plane, the parameters for tibiofibular syndesmosis were measured in different image modalities. All variables were significantly different between females and males (p < 0.05). CONCLUSIONS 3-D measurement technique could be helpful to identify the precise measurement planes for syndesmosis, which were not at the fixed level above the tibial plafond because of the sex difference. In this plane, reliable measurement results could be provided, in either 2-D or 3-D MDCT images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic evaluation of the ankle syndesmosis.

BACKGROUND Radiographic measurements to document ankle anatomy have been suggested in recent literature to be inadequate. Focus has been put on stress views and computed tomography; however, there are also issues with these modalities. An orthogonal view that could be used both statically and dynamically could help determine syndesmotic stability. The purpose of this study was to determine a pa...

متن کامل

CT characterizing the anatomy of uninjured ankle syndesmosis.

Although it is expert opinion that transsyndesmotic screws are placed obliquely 30° from posterolateral to anteromedial in the transverse plane, this has not been formally studied, and there is inconsistency regarding the congruency of the distal tibiofibular joint. Thirty-eight computed tomography (CT) scans of the lower extremity were used to examine the rotational profile of the axis of the ...

متن کامل

Evaluation of morphometric characteristics of the fibular incisura on dry bones.

OBJECTIVES The purpose of this study was to determine the anatomical characteristics of the fibular incisura of the tibia and the distal end of the fibula that form together the tibiofibular syndesmosis joint and to obtain the morphometric data in both genders. MATERIALS AND METHODS Current study has been performed on 35 dry adult tibia-fibula sets (22 males and 13 females). RESULTS 35% of ...

متن کامل

Sonographic evaluation of lower extremity interosseous membrane injuries: retrospective review in 3 patients.

OBJECTIVE To describe the sonographic findings of lower extremity interosseous membrane disruption with computed tomographic and surgical correlation. METHODS Three patients with sonographic evaluation of the lower extremity interosseous membrane were identified through the clinical experience of 1 author over a 5-year period. Sonographic images of the symptomatic and unaffected lower extremi...

متن کامل

Protective effects of pomegranate seed oil on ovariectomized rats as a model of postmenopausal osteoporosis: A multi-detector computed tomography evaluation

The pomegranate seed oil (PSO), containing 17-α-estradiol, is one of the newly found phytosterols with synergistic health effects on estrogen related physiological conditions. Herein, PSO was assessed for its potential improving effects on bone characteristics in a rat model of menopausal syndrome. Three month old non-pregnant female Wistar rats (n = 30) were either sham-operated (SHAM) or ovar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2015